STEP BY STEP GUIDE TO PROGRAMMING THIS ALARM
FOR FIRST TIME AND WHEN CHANGING BATTERIES
| Action: | Alarm Will Say: |
|
| 1. Insert batteries (2, AA batteries). | “Welcome, First Alert Carbon | |
|
| Monoxide Alarm.” | |
|
| “No location programmed” if first | |
|
| time or “[Location, example: | |
|
| “Basement”] location programmed” | |
|
| when changing batteries. | |
|
| “To select location, press and hold | |
|
| test button now.” | |
| 2. Press & Hold Test Button if you | “To save location, press and hold test | |
| would like to program the location | button after location is heard.” Alarm | |
| or change the location of the | will speak list of locations (see | |
| Alarm. Release button after Alarm | below). | |
| responds. |
|
|
|
|
|
|
| 3. After you hear the location of where | “[Location, example: “Basement”] | |
| you are placing the Alarm, Press & | location saved.” | |
| Hold the Test Button. | If no location is chosen: | |
|
| “No location saved.” |
Your Alarm has now been programmed for the location of your choice. Available locations:
Basement | Kitchen | Child’s Bedroom |
Living Room | Dining Room | Master Bedroom |
Family Room | No Location | Guest Bedroom |
Office | Hallway | Utility Room |
ADDING AND LINKING ADDITIONAL ONELINK® ALARMS
NOTE: Steps 1 through 3 need to be completed within two minutes. If more than two minutes pass, the Green power LED will stop blinking. Simply open the battery drawer of the second Alarm and repeat steps 1 through 3.
1.Insert the batteries into the battery drawer of the next Alarm.
DO NOT CLOSE THE DRAWER.
2. Press and hold the test button and then close the battery drawer.
3. Once you hear the unit chirp, release the test button. The Green power LED will start to blink indicating the ONELINK® Alarm is waiting for program data
from one of the other setup ONELINK® Alarms.
4.Press and hold the test button on the first Alarm, until the second Alarm chirps and its Green power LED stops blinking. Then release the test button.
5.If you have purchased the hardwired battery
6.Repeat steps
You have now successfully linked your new ONELINK® Alarms. To add additional Alarms at a later time, follow steps 1 through 5.
WHAT YOU WILL SEE AND HEAR WITH THIS ALARM
Under Normal Operations
Voice: Silent
Horn: Silent
Power LED: Flashes Green once/minute
When You Test the Alarm
Voice: “Testing.” Horn: 4 fast beeps, pause, 4 fast beeps;
Voice: “Warning, evacuate carbon monoxide in [Location, example: “Basement”]. Evacuate.” Pause. “Highest carbon monoxide level was [CO level example: _0_ ppm]”.
CO LED: Flashes Red in sync with the horn pattern
If Battery Becomes Low or is Missing
Voice: “Replace battery in [Location, example “Basement”].” Repeated every 5 hours
Horn: chirps once a minute
Power LED: Flashes Green On for 2 seconds/Off for 2 seconds. Low Battery Latch is now engaged.
If Alarm is Not Operating Properly (MALFUNCTION SIGNAL)
Voice: “Detector error in [Location, example “Basement”], please see manual.” Repeated every 5 hours
Horn: Three rapid chirps every minute
CO LED: Flashes approximately once a minute
Alarm Levels of CO are Detected
Horn: 4 fast beeps, pause, 4 fast beeps, pause*
Voice: “Warning, evacuate carbon monoxide in [Location, example: “Basement”]. Evacuate.” Pause. “Highest carbon monoxide level was [CO level example: ___ ppm]”.
Horn: 4 beeps, pause, 4 beeps, pause repeating 2 times followed by Voice Warning above.
CO LED: During Alarm: Flashes Red in sync with the horn pattern. After Alarm: Flashes Red On for 2 seconds/Off for 2 seconds. CO Alarm Latch is now engaged.
*NOTE: If unit goes into CO alarm, the regular 4
CO Alarm is Silenced
Horn: Off
CO LED: Flashes Red
4