REGULAR MAINTENANCE

REGULAR MAINTENANCE

This unit has been designed to be as maintenance-free as possible, but there are a few simple things you must do to keep it working properly.

Use only the replacement batteries listed below. The unit may not operate properly with other batteries. Never use rechargeable batteries since they may not provide a constant charge.

Test it at least once a week.

Clean the Smoke/CO Alarm at least once a month; gently vacuum the outside of the Smoke/CO Alarm using your household vacuum’s soft brush attachment. A can of clean compressed air (sold at computer or office supply stores) may also be used. Follow manufacturer instructions for use. Test the Smoke/CO Alarm. Never use water, cleaners or solvents since they may damage the unit.

If the Smoke/CO Alarm becomes contaminated by excessive dirt, dust and/or grime, and cannot be cleaned to avoid unwanted alarms, replace the unit immediately.

Relocate the unit if it sounds frequent unwanted alarms. See “Where This Alarm Should Not Be Installed” for details.

Choosing a replacement battery:

Your Smoke/CO Alarm requires two standard AA batteries. The following batteries are acceptable as replacements: Eveready Energizer E91. These

batteries are available at many local retail stores.

Actual battery service life depends on the Smoke/CO Alarm and the environ- ment in which it is installed. All the batteries specified above are acceptable replacement batteries for this unit. Regardless of the manufacturer’s suggested battery life, you MUST replace the battery immediately once the unit starts “chirping” (the “low battery warning”).

To replace the batteries (without removing

Alarm from the ceiling or wall):

1. Open the battery compartment.

2. Press tabs A and B as shown in the diagram and remove each battery.

3. Insert the new batteries, making sure they

AB

snap completely into the battery compartment.

Match the terminals on the ends of the

 

batteries with the terminals on the unit.

 

4. Close the battery compartment, and then test the unit by pressing the Test/Silence button.

IF YOUR SMOKE/CO ALARM SOUNDS

WHAT TO DO FIRST–IDENTIFY THE TYPE OF ALARM

Type of Alarm

What You See and Hear

Carbon Monoxide (CO)

CO LED: Flashes Red

 

Horn: 4 beeps, pause, 4 beeps, pause

 

Power/Smoke LED: Off

 

 

Smoke

Power/Smoke LED: Flashes Red

 

Horn: 3 beeps, pause, 3 beeps, pause

 

CO LED: Off

 

 

IF THE CO ALARM SOUNDS

“ALARM-MOVE TO FRESH AIR”

If you hear the CO alarm horn and the CO red light is flashing, move everyone to a source of fresh air. DO NOT remove the batteries!

Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. In other words, when your CO Alarm sounds, you must not ignore it!

IF THE CO ALARM SIGNAL SOUNDS:

1.Operate the Test/Silence button.

2.Call your emergency services, fire department or 911. Write down the number of your local emergency service here:

__________________________________________________________________

3.Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re- enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.

4.After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to inves- tigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here:

__________________________________________________________________

IF THE SMOKE ALARM SOUNDS

RESPONDING TO AN ALARM

If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous situation that requires your immediate attention. NEVER ignore any alarm. Ignoring the alarm may result in injury or death.

Never remove the batteries from a battery operated Smoke/CO Alarm to stop an unwanted alarm (caused by cooking smoke, etc.). Removing batteries disables the alarm so it cannot sense smoke, and removes your protection. Instead open a window or fan the smoke away from the unit. The alarm will reset automatically.

If the unit alarms get everyone out of the house immediately.

WHAT TO DO IN CASE OF FIRE

Don’t panic; stay calm. Follow your family escape plan.

Get out of the house as quickly as possible. Don’t stop to get dressed or collect anything.

Feel doors with the back of your hand before opening them.

If a door is cool, open it slowly. Don’t open a hot door. Keep doors and windows closed, unless you must escape through them.

Cover your nose and mouth with a cloth (preferably damp). Take short, shallow breaths.

Meet at your planned meeting place outside your home, and do a head count to make sure everybody got out safely.

Call the Fire Department as soon as possible from outside. Give your address, then your name.

Never go back inside a burning building for any reason.

Contact your Fire Department for ideas on making your home safer.

Alarms have various limitations. See "General Limitations of Smoke/CO Alarms" for details.

USING THE SILENCE FEATURES

Never remove the batteries to quiet an unwanted alarm. Removing the batteries disables the alarm and removes your protection.

The Silence Feature is intended to temporarily silence the horn while you identify and correct the problem. Do not use the Silence Feature in emergency situations. It will not correct a CO problem or extinguish a fire.

The Silence Feature can temporarily quiet an unwanted alarm for several minutes. Press the Test/Silence button on the alarm cover for at least 3-5 seconds.

After the Test/Silence button is released, the Red LED blinks during the silence mode.

When the Smoke Alarm is Silenced

When the CO Alarm is Silenced

 

 

The Smoke Alarm will remain silent for

The CO alarm will remain silent for

up to 15 minutes, then return to normal

up to 4 minutes.

operation.

After 4 minutes, if CO levels remain

If the smoke has not cleared–or

potentially dangerous the horn will

continues to increase–the device

start sounding again.

will go back into alarm.

 

SILENCING THE LOW BATTERY WARNING

This silence feature can temporarily quiet the low battery warning “chirp” for up to 8 hours. Press the Test/Silence button on the alarm cover.

Once the low battery warning “chirp” silence feature is activated, the unit continues to flash the Green light twice a minute for 8 hours. After 8 hours, the low battery “chirp” will resume. Replace the batteries as soon as possible; this unit will not operate without battery power!

To deactivate this feature: Press the Test/Silence button again. The unit will go into Test Mode and the low battery warning will resume (LED flashes and unit sounds “chirp” once a minute).

NOTE: A qualified appliance technician is defined as “a person, firm, corporation, or company that either in person or through a representative, is engaged in and responsible for the installation, testing, servicing, or replacement of heating, ventilation, air conditioning (HVAC) equipment, combustion appliances and equipment, and/or gas fireplaces or other decorative combustion equipment.”