10
Installation instructions
Connecting the cooktop to the mains power supply
Important!
This cooktop must be connected to the mains power supply only by a suitably qualified person.
This cooktop must be earthed.
Before connecting the cooktop to the mains power supply, check that:
1
the domestic wiring system is suitable for the power drawn by the cooktop
2
the voltage corresponds to the value given on the rating plate
3
the power supply cable sections can withstand the load specified on the rating plate.
To connect the cooktop to the mains power supply, do not use adapters, reducers, or branching
devices, as they can cause overheating and fire.
The power supply cable must not touch any hot parts and must be positioned so that its
temperature will not exceed 75
o
C at any point.
Power supply
CE302C 2900W @ 220-240V~ (12.6 A)
CE604L 6000W @ 220-240/380-415V 3N~ (26 A)
CE604C 6400W @ 220-240/380-415V 3N~ (27.8 A)
CE905C 8400W @ 220-240/380-415V 3N~ (36.5 A)
Important!
Check with an electrician whether the domestic wiring system is suitable without alterations. Any
alterations must only be made by a qualified electrician.
Connection diagrams
Single-phase connection
CE604L, CE604C, CE905C
CE302C
Two-phase connection Three-phase connection
PE
1
2
3
4
5

N (L2)L1

220 - 240 V

PE
1
2
3
4
5

380 - 415 V 3N

N

L3L1L2
PE
1
2
3
4
5

380 - 415 V 2N

N

L1L2
PE
N(L )
L12