Preparing the rangehood for installation

4

Installation instructions

Preparing the rangehood for installation

Ensure the overhead cabinets are built according to Fig.5 (below).

Before drilling any holes, check that the area behind the surface to be drilled is clear of any electrical cables or pipes etc.

Recirculated installation

Knockouts (remove for ducted only)

 

If the rangehood is to be installed as a recirculated hood,

 

 

first ensure the cabinets are built according to Fig. 5 below:

 

1

Do not remove the knockouts shown in Fig.4. These are

 

 

removed for ducted options only.

 

2

Remove Cover Tape “A”. See Fig.4.

 

 

Note: for recirculation, please purchase a charcoal

 

 

filter (refer to Accessories list on page 2).

 

3

If an 80 mm handle is not installed (depending on model

 

 

purchased), remove front fascia “B” by undoing the 3 screws

 

 

on the fascia (see Fig. 4).

Fig.4 Preparing for install

4

Replace front fascia “B” with a replacement front panel “C”,

 

constructed of same or similar material as the surrounding

 

 

cupboard doors. See Fig. 5 for height of panel.

Filtered air

 

Ducted installation

 

 

 

If the rangehood is to be installed as a ducted hood:

 

1

Remove the appropriate knockout to suit rear or top

 

 

venting, as shown in Fig.4

 

2

Do not remove Cover Tape “A”. See Fig.4. This is removed

Cooking fumes

 

for recirculating only.

Fig.5 Panel heights

 

 

Mounting the rangehood

The rangehood can be mounted in two ways, top or sides.

Before commencement, unpack the rangehood and check that it functions correctly.

Mounting to underside of cupboard

Fix the rangehood to a shelf mounted at the right height in your wall units, by drilling 4 holes, 5 mm in diameter, (see Fig.6) and fixing with the 4 screws supplied (found in the bag labelled “TOP FIXING”).

For top ducting cut hole to suit size Dimensions shown are for UNIDUCT

Drill 5 mm holes

Wall

Cupboard

Recirculated installationDoor

Fig.6 Mounting to underside of cabinetry

Page 6
Image 6