Fisher LNS-T32, LNS-T31A, LNS-W31A manual Lens Replacement Procedure for C Type, Remove the Lens

Models: LNS-T32 LNS-W31A LNS-T31A

1 18
Download 18 pages 52.79 Kb
Page 7
Image 7

LENS REPLACEMENT PROCEDURE (FOR "C" TYPE )

Perform the steps 1 to 6 for lens replacement.

First set the lens at the fully lower position with lens shift adjustment.

1 REMOVE THE LENS COVER AND FRONT CABINET

1.Turn the lens cover to counter-clockwise and pull it toward front and remove the Lens Cover.

2.Remove 2 Screws-A.

3.Remove the front cabinet

2 REMOVE THE LIGHT-BLOCK SHEET BASE AND LIGHT-BLOCK SHEET

1.Slide the light-block sheet base upward and remove it.

2.Remove the light-block sheet from lens.

SCREW "A"

FRONT CABINET

LENS COVER

LIGHT-BLOCK

SHEET BASE

LIGHT-BLOCK

SHEET

LENS COVER

FRONT

CABINET

3 REMOVE THE LENS

1.Grasp the Lens Lock Lever and turn it fully upward. Remove the Lens into the projector.

2.Disconnect the lens motor lead connector to the socket on the lens attachment.

3.Remove 4 Screws and remove lens attachment.

Pull the Lens Lock Lever upward

LENS LOCK LEVER

LENS

SCREWATTACHMENT

SOCKET

CONNECTOR

LENS MOTOR

LEAD

- 7 -

Page 7
Image 7
Fisher LNS-T32, LNS-T31A Lens Replacement Procedure for C Type, Remove the LIGHT-BLOCK Sheet Base and LIGHT-BLOCK Sheet