SETTING

Power management

This function turns Projection Lamp off when this projector detects signal interruption and is not used for a certain period in order to reduce power consumption and maintain Lamp-life. (This projector is shipped with this function ON.)

Power Management function operates to turn Projection Lamp off when input signal is interrupted and any button is not pressed over 5 minutes. This function operates as follows;

1.When any input signal is interrupted, “No signal” and counting down display appears (for 5 minutes).

2.After counting down for 5 minutes, projector lamp and READY indicator are turned off.

3.When READY indicator flashing, Projection Lamp can be turned on again (Power Management mode).

In this Power Management mode, Projection Lamp is automatically turned on when input signal connected or projector is operated with any button on Top Control or on Remote Control Unit again.

Time left until Lamp off.

Press SELECT button at this icon to display other items.

On start

When this function is “On,” projector is automatically turned on just by connecting AC Power cord to a wall outlet.

Note ; Be sure to turn projector off properly (refer to section “TURNING OFF PROJECTOR” on P19). If projector is turned off in wrong steps, On Start function does not operate properly.

Remote control

This projector has two different remote control codes; factory-set normal code (Code 1) and secondary code (Code 2). This switching function prevents remote control operation mixture (jam) when operating several projectors or video equipment together.

When operating projector in “Code 2,” both projector and Remote Control Unit must be switched to “Code 2.”

To change code of Projector;

Set Remote control in SETTING MENU to “Code 2.”

To change code of Remote Control Unit;

Press both MENU and IMAGE buttons on Remote Control Unit together for over 10 seconds.

After changing code, make sure Remote Control operates properly. To return to normal code (Code 1), operate both projector and Remote Control in ways above again.

NOTE : When batteries of Remote Control Unit are replaced or ALL- OFF switch is turned to “ALL-OFF,” remote transmit code automatically returns to normal code (Code 1).

Lamp counter reset

This function is used to reset Lamp Replace Counter. When replacing Projection Lamp, reset Lamp Replace Counter by using this function. Refer to page 39 for operation.

On start

Press SELECT button at this icon to display previous items.

Move pointer to item and then press

POINT LEFT/RIGHT button(s).

Move pointer to Lamp counter reset and then press SELECT button. Message “Lamp replace counter reset?” is displayed.

36