Power

Power

Main unit and remote: Lithium-ion battery pack, 7.4 V, 4000 mAh

 

• Typical battery life: 12 to 14 hours

 

• Charge time (with tester off): 4 hours (below 40 °C)

 

• AC adapter/charger, USA version: Linear power supply; Input 108 V ac to 132 V ac, 60 Hz ;

 

Output 15 V dc, 1.2 A

 

• AC adapter/charger, international version: Switching power supply; Input 90 V ac to 264 V ac,

 

48 to 62 Hz; Output 15 V dc, 1.2 A (isolated output)

 

• Memory backup power in main unit: Lithium battery

 

• Typical life of lithium battery: 5 years

 

• The battery will not charge at temperatures outside of 0°C to 45°C (32°F to 113°F).

 

The battery charges at a reduced rate between 40°C and 45°C (104°F and 113°F).

 

 

Languages Supported

English, French, German, Spanish, Russian and Italian

 

 

Calibration

Service center calibration period is 1 year

 

 

Performance Specifications

Note: all specifications for tests on twisted-pair cabling apply to 100 Ω cable. Contact Fluke Networks

 

for information on measurement performance for cable with a different impedance.

 

 

Baseline accuracy

The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV in

 

2nd Edition of IEC 61935-1 over the frequency range supported by the tester.

 

 

Category 6/Class E link

DTX CableAnalyzer far exceeds Level III requirements of TIA/EIA-568-B.2-2 and IEC 61935-1

test modes (and lower link

 

categories)

 

 

 

Length for Twisted Pair Cabling

(Length specs do not include the uncertainty of the cable’s NVP Value)

Parameter

Range

Resolution

Accuracy

Single-ended Test

Dual-ended Test (Main and Remote)

800 m (2600 ft)

150 m (490 ft)

0.1 m or 1 ft

0.1 m or 1 ft

± (1m + 4%)

± (1m + 4%)

 

 

Delay Skew

Parameter

Range

Resolution

Accuracy

Twisted Pair Cabling

0 ns to 100 ns

1 ns

± 10 ns

DC Loop Resistance Test

Parameter

Twisted Pair Cabling

 

 

Range

O Ω to 53Ω

 

 

Resolution

0.1 Ω

 

 

Accuracy

± (1 Ω + 1%)

 

 

Overload Recovery Time

Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after repeated or

 