FLK-TI-SBC3

FLK-TI-SBC3

Charging Base/Power Supply with Adapters

Instruction Sheet

The Fluke FLK-TI-SBC3 Charging Base/Power Supply with Adapters charges the Fluke FLK-TI-SBP3 Smart Battery Pack for Thermal Imagers. The FLK-TI-SBC3 consists of a charging base, power supply, and power outlet adapters.

 

Y

 

TTER

 

BA 3

 

CHARGER

 

RT

 

SMA

SBC3

 

Ti

 

POWER

PN 3481481 August 2009

Safety Information

Use the FLK-TI-SBC3 only as specified in this instruction sheet or other Fluke product‑specific manual. See Table 1 for a list of symbols used on the FLK-TI-SBC3.

A Warning identifies hazardous conditions and actions that could cause bodily harm or death.

A Caution identifies conditions and actions that could damage the Imager or cause permanent loss of data.

WWarning

To avoid injury:

●●

Do not disassemble or short circuit the battery pack.

●●

Do not expose the battery pack to temperatures above 50 °C (122 °F).

●●

Do not incinerate or mutilate the battery pack.

●●

Use only ac adapters approved by Fluke for the product to charge the battery or

 

power the product.

 

 

Table 1. Symbols

 

 

 

 

Symbol

Description

 

P

Conforms to requirements of European Union and European Free Trade Association.

 

 

 

 

"

Imager connected to battery charger.

 

 

 

 

;

Conforms to relevant Australian standards.

 

)

Conforms to relevant Canadian and US standards

 

 

 

 

W

Important information. See manual.

 

 

 

 

~

Do not dispose of this product as unsorted municipal waste. Go to Fluke’s website for

 

recycling information.

Charging the Battery

Before using the battery pack for the first time, charge the battery in the two-bay charging base for at least two and one-half hours. For complete charging instructions, see the “Ti32, TiR32 Thermal Imagers User Manual.”

Specifications

See Table 2 for the specifications.

Table 2. Specifications

Battery Charging

10-15 Vdc 2 A or charge battery pack in Imager with included ac

adapter rated: 100-240 Vac 50/60 Hz, 15 V 2 A.

 

 

 

 

 

 

Status

Charging LED

Power LED

 

 

 

 

 

off

no battery detected

no dc power input

Charging / Power LED

 

 

 

solid green

charged

dc power present

 

 

 

 

 

blinking green

charging

na

 

 

 

 

 

blinking red

fault

na

 

 

 

 

Dimensions

159.5 mm x 68.9 mm x 51.3 mm (6.28 in x 2.71 in x 2.02 in)

Operating Temperature

-10 °C to 70 °C (-14 °F to 158 °F)

 

 

 

Storage Temperature

-20 °C to 80 °C (-4 °F to 176 °F) without batteries

Humidity Range

10 % to 95 % non-condensing

 

 

 

 

 