Cables

3.Do not use the trimmer if the electric cables are damaged or worn.

4.Immediately disconnect from the mains electricity sup- ply if the cable is cut, or the insulation is damaged. Do not touch the electric cable until the electrical sup- ply has been disconnected. Do not repair a cut or damaged cable. Replace it with a new one.

5.Your extension cable must be uncoiled, coiled cables can overheat and reduce the efficiency of your trimmer.

6.Keep the cable clear of the cutting area and obsta- cles at all times.

7.Do not pull cable around sharp objects.

8.Always switch off at the mains before disconnecting any plug, cable connector or extension cable.

9.Never pull on the cable to disconnect any of the plugs.

10.Switch off, remove plug from mains and examine electric supply cable for damage or ageing before winding cable for storage. Do not repair a damaged cable, replace it with a new one. Use only Flymo replacement cable.

11.Always wind cable carefully, avoiding kinking.

12.Use only on AC mains supply voltage shown on the product rating label.

13.Flymo trimmers are double insulated to EN60335. Under no circumstance should an earth be connect-

ed to any part of the trimmer.

Preparation

1.While using your product always wear substantial footwear and long trousers.

2.Before using the machine and after any impact, check for signs of wear or damage and repair as necessary.

3.Inspect the area to be cut before each use. Remove all objects such as stones, broken glass, nails, wire, string etc, which can be thrown or become entan- gled in the trimmer head.

4.Check that the cutting head is fitted correctly.

Use

AVOID ACCIDENTAL STARTING. REMOVE PLUG FROM MAINS AND KEEP FEET AWAY FROM THE SWITCH LEVER WHEN:- CLEANING AROUND THE INSIDE OF THE SAFETY GUARD, REMOVING OR

REFITTING SPOOL CAP, MANUALLY FEEDING OR REPLACING NYLON LINE.

1.Use the trimmer only in daylight or good artificial light.

2.Avoid operating your trimmer in wet grass, where feasible.

3.Take care in wet grass, you may lose your footing.

4.On slopes, be extra careful of your footing and wear non-slip footwear.

5.Do not walk backwards when trimming, you could trip. Walk never run.

6.Keep cutting head below waist level.

7.Switch off before pushing the trimmer over surfaces other than grass.

8.Never operate the trimmer with damaged guards or without guards in place.

9.Never fit metal cutting elements.

10.Keep hands and feet away from the cutting means at all times and especially when switching on the motor.

11.Never pick up or carry a trimmer by the cable.

12.Do not lean over the trimmer guard - objects may be thrown by the cutting line.

13.Remove the plug from the mains :

-before leaving the trimmer unattended for any period;

-before clearing a blockage;

-before checking, cleaning or working on the appliance;

-if you hit an object. Do not use your trimmer until you are sure that the entire trimmer is in a safe operating condition;

-if the trimmer starts to vibrate abnormally. Check

immediately. Excessive vibration can cause injury.

Maintenance and storage

1.Keep all nuts, bolts and screws tight to be sure the trimmer is in safe working condition.

2.Replace worn or damaged parts for safety.

3.Only use the replacement cutting line specified for this product.

4.Only use replacement parts and accessories recom- mended by Electrolux Outdoor Products.

5.To avoid the risk of injury keep fingers and hands clear of the line cutter on the leading edge of the guard.

6.Inspect and maintain the trimmer regularly. Any repairs must be carried out by an authorised repair- er.

Cables

IMPORTANT

Use only 1.00mm2 size cable up to 40 metres length maximum.

Maximum rating:

1.00mm2 size cable, 10 amps 250 volts AC.

THE POWER TRIM IS SUPPLIED WITH AN ELECTRIC MAINS CABLE WIRED DIRECTLY INTO THE PRODUCT.

1.Flymo Mains Cables and Extension Cables are available from your local Electrolux Outdoor Products Approved Service Centre.

2.Do not wire an extension cable directly to your prod- uct yourself. Please contact your local Electrolux Outdoor Products Approved Service Centre for further information on the connectors and kits available.

3.Only use extension cables specifically designed for

outdoor use.

CONNECTORS

Flymo connectors are suitable for use with 2 core cable only. Under no circumstances should these connectors be used for earthed products.

All Flymo connectors and cables are of splashproof construction. They are not waterproof and must not be left outside permanently nor should they be submerged or immersed in water. Do not let cable lay or trail through pools of water or splashed with water from hose pipes.

MAINS PLUG REPLACEMENT

If the plug supplied is cut off it should be destroyed. There is an electric shock hazard if a cut off plug is inserted into a 13 amp socket.

1.No earth required. Flymo products are double insulated to EN60335 and under no circumstances should an earth be connected to any part of the product.

2.Ensure the mains voltage suits your product.

3.IMPORTANT!

The wires in the mains lead are coloured in accordance with the following code:

BLUE- NEUTRAL

BROWN - LIVE

The wire which is coloured BLUE must be connected to the Terminal which is marked with the letter ‘N’ or coloured BLACK. The wire which is coloured BROWN must be connected to the Terminal which is marked with the letter ‘L’ or coloured RED.

4.It is important that the outer sheath is clamped cor- rectly into the 3-pin plug.

5.If in doubt consult your local Service Repairer or qualified electrician before the machine is used.

6.A 5 Amp fuse must be fitted to the Mains Plug.

7.The normal plug fuse and household fuse only pro- tect the electrical equipment and are not a safe- guard against electrocution.

If your product is hard wired i.e. non-detachable mains electric cable, a conversion kit and exten- sion cable is available from all Electrolux Outdoor Products Approved Service Centres which can be found in your local Yellow Pages.

Page 3
Image 3
Flymo 511967501 manual Cables