Troubleshooting

WARNING: Turn off and unplug fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace.

CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM POSSIBLE CAUSE

REMEDY

Whenignitorbuttonispressed, there is no spark at ODS/ pilot

1.

Ignitor electrode not con-

1.

Reconnect ignitor cable

 

nected to ignitor cable

 

 

2.

Ignitor cable pinched or

2.

Free ignitor cable if pinched

 

wet

 

by any metal or tubing.

 

 

 

Keep ignitor cable dry

3.

Broken ignitor cable

3.

Replace ignitor cable

4.

Bad piezo ignitor

4.

Replace piezo ignitor

5.

Ignitor electrode positioned

5.

Replace pilot assembly

 

wrong

 

 

6.

Ignitor electrode broken

6.

Replace pilot assembly

Whenignitorbuttonispressed, there is spark at ODS/pilot but no ignition

1.Gas supply turned off or equipment shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when in- stalled

5.Depleted gas supply (pro- pane/LP only)

6.ODS/pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open equipment shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat ignit- ing operation until air is removed

5.Contact local propane/LP gas company

6.Clean ODS/pilot (see Cleaning and Maintenance, page 20) or replace ODS/ pilot assembly

7.Replace gas regulator