FMI FMH26TN Inspecting Burner, To Turn Off Gas To Appliance, Thermostat Control Operation

Models: FMH26TN

1 28
Download 28 pages 40.25 Kb
Page 18
Image 18
TO TURN OFF GAS

NATURAL GAS VENT-FREE FIREPLACE SYSTEM

OPERATING

FIREPLACE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1.Turn control knob clockwise Shutting Off Fireplace to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise Shutting Off Burner Only (pilot stays lit) to the PILOT position.

THERMOSTAT

CONTROL OPERATION

The thermostatic control used on this fire- place differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this fireplace senses the room tempera- ture. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature.

The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the fireplace cabinet. This may not always agree with room temperature (depend- ing on housing construction, installation location, room size, open air tempera- tures, etc.). Frequent use of your fire- place will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 17.

2.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, page 17.

OPERATING BLOWER

This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF posi- tion, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.

Note: Your fireplace and thermostat blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blower turned off. However, the blower helps distribute heated air from the fireplace.

Auto/Off/On Switch

ON

OFF

Figure 30 - Auto/Off/On Switch

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 31 shows a correct pilot flame pattern. Figure 32 shows an incorrect pilot flame pattern. The incorrect pilot flame is not prop- erly heating the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the fireplace will shut down.

If pilot flame pattern is incorrect, as shown in Figure 32

turn fireplace off (see To Turn Off Gas to Appliance)

see Troubleshooting, pages 20 through 22

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Thermocouple

Pilot Burner

Figure 31 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Figure 32 - Incorrect Pilot Flame Pattern

18

107105

Page 18
Image 18
FMI FMH26TN Inspecting Burner, To Turn Off Gas To Appliance, Thermostat Control Operation, Manual Lighting Procedure

FAQ

How do I turn off the gas to my FMI FMH26TN fireplace?

To turn off the gas to your fireplace, simply turn the control knob clockwise to the OFF position. Make sure to also turn off all electric power to the appliance if service is to be performed.

How does the thermostat control work on the FMI FMH26TN fireplace?

The thermostat on this fireplace senses the room temperature and adjusts the amount of gas flow to the burner, increasing or decreasing the flame height. It will shut off the burner if the room exceeds the set temperature and cycle back on when the temperature drops.

How do I manually light the pilot on my FMI FMH26TN fireplace?

To manually light the pilot, follow the lighting instructions on page 17 of the manual, and keep the control knob pressed in for 30 seconds after lighting the pilot.