SAFETY

Continued

You must operate this appliance with the fireplace screen and hood in place. Make sure fireplace screen and hood are in place before running appliance.

Keep the appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any struc- ture. Locate propane/LP supply tank(s) outdoors (propane/ LP units only).

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire depart- ment

4.This appliance shall not be installed in a bedroom or bath- room, unless installed as a vented appliance. See Installing Damper Clamp Accessory for Vented Operation, page 6. This gas log set may not be installed as a vented appli- ance in a bedroom or bathroom in the Commonwealth of Massachusetts.

5.Before installing in a solid fuel burning fireplace, the chim- ney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, repair flue and firebox before operating appliance.

6.If fireplace has glass doors, never operate this appliance with glass doors closed. If you operate appliance with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across open- ings of fireplace.

7.To prevent the creation of soot, follow the instructions in

Cleaning and Maintenance, page 16.

8.Before using furniture polish, wax, carpet cleaner or similar products, turn appliance off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls and furniture.

9.Do not use this appliance as a wood burning appliance. Use only the logs provided with the appliance. Do not burn solid fuels in this appliance.

10.Do not run appliance

where flammable liquids or vapors are used or stored

under dusty conditions

11.Do not use this appliance to cook food or burn paper or

other objects.

12.Do not use this appliance if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the room appliance and to replace any part of the control system and any gas control which has been under water.

13.Do not operate appliance if any log is broken.

14.Turn appliance off and let cool before servicing, installing or repairing. Only a qualified service person should install, service or repair appliance.

15.This appliances must not be connected to any external electrical source.

16.Operating appliance above elevations of 4,500 feet may cause pilot outage.

17.To prevent performance problems, do not use propane/ LP fuel tank of less than 100 lb. capacity (propane/LP units only).

18.Provide adequate clearances around air openings. 19.Do not operate fireplace if any log is broken.

If used with MFEB accessory ember burner, this appliance shall only be installed in a wood burning fireplace.

Product Identification

MF Model Series

Figure 1 - Product Identification

125636-01A

www.fmiproducts.com