Installation
Continued
Area of Various Standard Round Flues
Diameter Area
5" 20 sq. inches
6" 29 sq. inches
7" 39 sq. inches
8" 51 sq. inches
Chimney Height Minimum Permanent Flue Opening
6' to 15' | 39 sq. inches |
15' to 30' | 29 sq. inches |
Damper
Clamp
Damper
Damper
Clamp
DamperDamper
Masonry Fireplace | Manufactured Fireplace |
Figure 8 - Attaching Damper Clamp
Installing appliance base assembly
INSTALLING Appliance BASE ASSEMBLY
WARNING: You must secure this appliance to fireplace floor. If not, appliance will move when you adjust controls. Moving appliance may cause a gas leak.
WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fireplace floor to allow access to appliance control panel. This will insure adequate air flow and guard against sooting and controls being dam- aged. Raise fireplace floor with noncombustible material. Make sure material is secure.
Installation Items Needed
•hardware package (provided with appliance)
•approved flexible gas hose and fittings provided (if allowed by local codes)
•sealant (resistant to propane/LP gas, not provided)
•electric drill with 3/16” masonry drill bit
1.Apply pipe joint sealant lightly to male threads of the 1/2 NPT side of gas fitting elbow (provided) and connect to inlet side of gas control. Remove gas fitting from flexible gas hose (provided) before connecting to elbow (see Figure 9).
2.Position appliance base assembly in fireplace.
3.Mark screw locations through holes in front panel of base (see Figure 10, page 8). If installing in a
4.Remove appliance base from fireplace.
5.Drill holes at marked locations using 3/16" drill bit.
6.Attach base, through holes in back side panels of base, to fireplace floor using masonry screws provided in hardware package (see Figure 10, page 8).
7.Connect to gas supply. See Connecting To Gas Supply, page 8.
| Flexible |
Gas Shutoff | Gas Line |
Do NOT | |
Valve | Kink |
Inlet Pressure Tap | Pilot Adjustment | |||
|
|
| MAI | N |
| IN |
|
|
|
PILO | TAD | PILOJ | T |
|
|
| OU | T |
|
1/2" NPT |
|
Incoming |
|
Gas Line | Outlet Pressure Tap |
Note: | Set Screw |
1)Wire connections not shown for clarity
2)* 1/8" NPT Plugged Tapping
Figure 9 - Connecting Incoming Gas Line to Flex Gas Line
www.fmiproducts.com | 7 |