Continued

Equipment Shutoff Valve

Gas Meter

Control Valve

Location

Figure 15 - Checking Gas Joints (Natural Gas Only)

Pressure Testing Appliance Gas

Connections

1.Open equipment shutoff valve (see Figure 13, page 9).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of appliance is in the OFF posi- tion.

4.Check all joints from gas meter to equipment shutoff valve for natural gas or propane/LP supply to equipment shutoff valve for propane/LP (see Figure 14, page 9 or Figure 15, page 10). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light appliance (see Operation, page 14). Check all other internal joints for leaks.

7.Turn off appliance (see To Turn Off Gas to Appliance, page 14).

Installing BATTERIES IN HAND HELD remote

CONTROL AND BATTERY PACK

Installing Batteries in Battery pack

1.Remove access cover on battery pack.

2.Install 4 AA batteries, included, into battery pack following positive and negative directions.

3.Replace access cover on battery pack.

4.Place battery pack next control valve away from the burner.

Installing Batteries in Handheld Remote Control

1.Remove battery cover on back of remote control.

2.Install supplied A23/12V battery following positive and negative directions.

3.Replace battery cover onto remote control.

MF SERIES BURNER SYSTEM-LOG COMPATIBILITY

CHART

Burner System Model

Refractory Concrete Logs

 

For Use With This Burner

 

System

 

 

MF42ONE,MF42OPE,

LMF42-SC

MF48ONE, MF48OPE,

LMF48-SC

Figure 16 - MF Series Burner System- Log Compatibility

Chart

INSTALLING LOGS and Lava Rock

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

CAUTION:Afterinstallationandperiodically thereafter,checktoensurethatnoflamecomes in contact with any log. With appliance set to Hi, check to see if flames contact any log. If so,repositionlogsaccordingtologinstallation instructions in this manual. Flames contacting logs will create soot.

LMF (42 AND 48)-SC SERIES LOG PLACEMENT

It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with appliance or as identified for use with the appliance as shown in Figure 18.

Note: Each log includes an identifying number cast in the log. Look at each log when placing them on the burner system to be certain it is correct.

Note: For additional information, go to www.fmiproducts.com and click on the technical Support tab for access to log placement videos.

1.Find the right front log (LMF42-SC: D-019 or LMF48-SC: D027). See Figures 17, 17A, 17B, and 17C for reference. The log has a rectangular shape on the bottom that fits against the lip on the black metal base, the square grate, and the round tube burner. Slide the log in place as shown in Figures.

10