www.fmiproducts.com 122273-01D8
Figure 9 - Lineal Gain
LINEAL GAIN
PART NO. DESCRIPTION GAIN
Georgian Fireplace 66 1/2
"
12-12DM
12-12HT Pipe Section 10 5/8
"
18-12DM
18-12HT Pipe Section 16 5/8
"
24-12DM
24-12HT Pipe Section 23 5/8
"
36-12DM
36-12HT Pipe Section 34 5/8
"
48-12DM
48-12HT Pipe Section 46 5/8
"
RLT-12D
RLT-12HT Round Termination 7 3/4
"
*
STL-12D Square Chase-Top
with Slip Section 7
"
to 15
"
*
* The lineal gain for the terminations is mea-
sured to the ue gas outlet height.
Hemmed
End
12 3/8"
Stainless
Inner Pipe
15" Galvanized
Outer Pipe

ASSEMBLY AND INSTALLATION OF

DOUBLE WALL CHIMNEY SYSTEM

Each double wall chimney section consists of a
galvanized outer pipe, a stainless steel inner ue
pipe and a wire spacer. The pipe sections must
be assembled independently as the chimney is
installed. When connecting chimney directly to
the replace, the inner ue pipe section must
be installed rst with the lanced side up. The
outer pipe section can then be installed over
5 the ue pipe section with the hemmed end
up. Press down on each pipe section until the
lances securely engage the hem on the replace
starter. The wire will assure the proper spacing
between the inner and outer pipe sections.
Figure 8 - Outside Air Kit
Secure to Collars with Metal Tape,
Screws or Straps (Min. of 1/4" x 20"
in size)
Air Inlet
Location
Must Allow
For Bushes
or Snow
Vent Hood
Required for
Wall Installation
Air Inlet
Eyebrow
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)

CHIMNEY PIPE

The FMI PRODUCTS, LLC chimney system
consists of 12", 18", 24", 36" and 48" snap-
lock, double-wall pipe segments, planned
for maximum adaptability to individual site
requirements. Actual lengths gained after
tting overlaps must be taken into consider-
ation (lineal gain) and are given in the lineal
gain chart (see Figure 9). Lineal Gain is the
actual measurable length of a part after two or
more parts are connected. For Canada, use
chimney parts designated "HT".
Venting inStallatiOn

OPTIONAL OUTSIDE AIR KIT

(MODEL AK4/AK4F)

The installation of an outside air kit should
be performed during the rough framing of
the replace due to the nature of it's location.
Outside combustion air is accessed through
a vented crawl space (AK4F) or through a
sidewall (AK4).
CAUTION: Combustion air inlet ducts shall not terminate in attic space.The maximum height for the air vent can not exceed 3 feet below the ue gas outlet of the termination. WARNING: The opening in the collar around the chimney at the top of the replace must not be obstructed. Never use blown insulation to ll the chimney enclosure.