Venting Installation

Continued

Minimum Measurements

 

14 3/8"

 

 

(36.5 cm)

1"

30"

 

 

(2.5

(76.2 cm)

 

cm)

1"

 

 

 

 

(2.5 cm)

 

1"

 

 

(2.5

 

 

cm)

 

 

 

Opening "A"

Storm Collar Installation (SC1 or SC2) Place storm collar over pipe and slide down until it is snug against the open edge of the flashing (see Figure 14). Use SC1 for all round terminations and SC2 for all terminations with slip sections.Apply waterproof caulk around the perimeter of the collar to provide a proper seal.

Chimney

Waterproof

Pipe

Caulk

Storm

Flashing

Collar

Pitch

Slope

Opening "A"

Used Flashing

 

 

Max.

Model No.

Flat

15"

V6F-8DM

0-6/12

26.6°

16 1/8"

V6F-8DM

6/12-

45.0°

20 3/8"

V12F-8DM

12/12

 

 

 

Figure 12 - Roof Opening Measurements

Flashing installation (v6f-8dm or v12f-8dm)

Determine the flashing to be used with the roof opening chart. Slide flashing over pipe until base is flat against roof. Replace as many shingles as needed to cover exposed area and flashing base. Secure in position by nailing through shingles (see Figure 13). DO NOT NAIL THROUGH FLASHING CONE.

Installing Flashing on a Metal Roof When installing flashing on a metal roof, it is required that putty tape be used between the flashing and roof. The flashing must be secured to the roof using #8 x 3/4" screws and then sealed with roof coating to prevent leakage through screw holes.Aroof coating must also be applied around perimeter of flashing to provide a proper seal.

Storm Collar

Overlap

Flashing

Shingles Top

and Sides Only

Cone

 

Nail Only

Outer

Perimeter

of Flashing

Figure 14 - Storm Collar

Terminations/Spark Arrestor

The fireplace system must be terminated with the listed round top or chase terminations. In any case, refer to the installation instructions supplied with the termination. The termination approved for this fireplace are the RT-8DM and RTL-8DM that can be used for flashing or chase and ET-8DM, ETO-8DM, ETL-8DM and ETLO- 8DM for chase style termination only. Figure 15 shows an RTL-8DM round top termination.

CAUTION: Do not seal openings on the rooftop flashing. Follow the installation instructions provided with the termination being used.

Attach Bracket

RTL-8D

Tabs to

Outer Pipe

Level of

(3 Places)

Flue Gas

Secure with

Outlet

Screws

Caulk

Overlap

Collar

Shingles Top

and Sides

Flashing

 

 

Underlap

Underlap Shingles

Shingles

Bottom Only

at Bottom

 

Figure 13 - Flashing Installation

Figure 15 - Termination