Specifications: S-Series S50V Power over Ethernet Switch
Ordering Information
ORDER NUMBER | DESCRIPTION | |
| SFP ports, two modular slots and PoE | |
GbE XFP Module* | ||
GbE CX4 Module* | ||
Gbps Stacking Module* | ||
Gbps Stacking Module* | ||
60cm stacking cable for | ||
4m stacking cable for | ||
60cm stacking cable for | ||
4m stacking cable for | ||
Redundant Power Supply Unit* | ||
| Includes one cable | |
Layer 3 Software Upgrade* |
* Optional module for the S50V
Physical
48
Optional Modules:
2
2
2
1
1
Size: 17.32 w x 16.73 d x 1.73" h (440 x 425 x 44 mm)
Weight: 15.62 lbs (7.10 Kg)
Power Supply: Primary
Max. Thermal Output: 560 BTU/hr
Max. Current Draw per System: 100vAC/4A, 240vAC/2A
Max. Power Consumption: 470W 19" rack mountable
Standard 1U chassis height Max. Operating Specifications:
Temperature: 14° to 131°F
Operating humidity: 10 to 90% (RH),
Storage Temperature:
Storage humidity: 10 to 90% (RH),
Redundancy
Redundancy in stack connectivity (self healing ring) Redundancy with up to 4 ports of 10 GbE uplinks Redundancy with dual modular slots
Redundancy with GbE uplinks – using Link Aggregation External Power Redundancy
Performance |
|
Layer 2 MAC Addresses: | 16K |
Layer 3 Forwarding Entries: Up to 3K LPM table and | |
| 4K host entries |
Switching Fabric Capacity: | 288 Gbps |
User Traffic Capacity: | 176 Gbps (131 Mpps) |
Jumbo Frame Support: | 9216 bytes |
Link Aggregation: | 8 links per Link Aggregation |
| Group & 48 groups per system |
Stacking Capacity: | Up to 96 Gbps |
Queues per port: | 8 Queues (8th queue |
| reserved for stacking) |
VLANs: | 1024 VLANs with 4096 tag |
| value support |
all protocols, including | |
| IPv4 and IPv6 |
IPv4 |
LAG load balancing based on Layer 2, IPv4 or IPv6 headers
IEEE Compliance
802.310Base-T
802.3u Fast Ethernet
802.3z Gigabit Ethernet 802.3ae 10 Gigabit Ethernet 802.3ak 10 Gigabit Ethernet CX4 802.3af Power over Ethernet 802.1p L2 Prioritization
802.1Q VLAN Tagging, Double VLAN Tagging
802.1s Multiple Spanning Tree Protocol
802.1w Rapid Spanning Tree Protocol 802.1AB Link Layer Discovery Protocol 802.3ad Link Aggregation with LACP 802.1D Bridging
802.3x Flow Control
RFC Compliance |
|
| |
OSPF: |
| 2154 | OSPF MD5 |
1765 | OSPF Database | ||
| overflow | 2328 | OSPF v2 |
1850 | OSPF MIB |
|
|
RIP: |
| 2082 | RIP MD5 |
1058 | RIP v1 | ||
1724 | RIP MIB | 2453 | RIP v2 |
IP Multicast: | 3376 | IGMPv3 | |
1112 | IGMP | ||
2236 | IGMPv1 and v2 | ||
2362 |
| v1 and v2 | |
General Routing and Switching Protocols: | |||
768 | UDP | 1256 | ICMP |
783 | TFTP | 1519 | CIDR |
791 | IP | 1542 | BootP (relay) |
792 | ICMP | 1812 | IP v4 routers |
793 | TCP | 1866 | HTML |
826 | ARP | 2068 | HTTP |
854 | Telnet | 2030 | SNTP |
894 | IP over Ethernet | 2131 | BootP/DHCP |
903 | Reverse ARP |
| helper |
951 | BootP | 2236 | IGMP v1 & v2 |
1027 | Proxy ARP | 2338 | VRRP |
Security: | 3128 | Protection Against | |
1492 | TACACS+ | ||
2865 | RADIUS |
| a Variant of the Tiny |
|
|
| Fragment Attack |
Port Security:
IP Broadcast Control
Quality of Service:
7 user queues per port IEEE 802.1p
IP DiffServ support Per port rate limiting Per queue rate limiting
Strict Priority and Weighted Round Robin Scheduling
Management and SNMP:
RADIUS/TACACS+ Authentication Secure
completion, Context sensitive help
1157 | SNMP v1 |
1212 | Concise MIB Definition |
1213 | SNMP v2 |
1493 | Bridge MIB |
1643 | |
1901 | Community based SNMPv2 |
1905 | Protocol Operations for SNMPv2 |
1906 | Transport Mappings for SNMPv2 |
1907 | Management Information Base for SNMPv2 |
1908 | Coexistence between SNMPv1 and SNMPv2 |
1724 | RIP v2 MIB extension |
1850 | OSPF v2 MIB |
2096 | IP forwarding table MIB |
2233 | The Interfaces Group MIB using SMI v2 |
2570 | SNMP v3 |
2665 | |
2674 | VLAN MIB |
2787 | VRRP MIB |
2819 | RMON (Groups 1,2,3,9) |
2933 | IGMP MIB |
2934 | PIM MIB for IPv4 |
Compliances
Safety
CUS 60950, 3rd edition (US NRTL through CSA) CSA 60950, 3rd edition
CE Mark (EN 60950)
CB Report, all country deviations
EN
EN 60825-2 Safety of Laser Products-Part 2:
Safety of Optical Fibre Communications Systems 21 CFR 1040.10 and 1040.11 FDA laser device
requirements
EMC
USA: FCC CFR47 Part 15, Subpart J, Class A
Canada:
Europe: EN55022 1998 (CISPR 22: 1997), Class A
Japan: VCCI V3/01.4 Class A
EN
EN
EN
EN
Equipment
EN 55024 1998
Telecoms
JATE (for Japan)
RoHS Compliance
All S50V components are EU RoHS compliant with the exception of lead, which is exempt from the directive for network equipment
Force10 Networks, Inc.
350 Holger Way
San Jose, CA 95134 USA www.force10networks.com
408-571-3500 PHONE
408-571-3550 FACSIMILE
© 2007 Force10 Networks, Inc. All rights reserved. Force10 Networks and
SSDS03 | 1007 v2.8 |