WARNING

A stud MUST be located and used for at least one side of the diaper changing station.

The diaper changing station is no stronger than the anchors or walls to which they are attached and, therefore, MUST be firmly secured in order to support the weight they are intended to support. Contact an architect or building contractor if any questions.

INSTALLATION

NOTE: If using a backer plate, go to “Using Backer Plate Mounting System” section.

1. Locate wood stud where left side of changing station will be mounted to the wall.

2. Measure up 61” (155 cm) from the floor and mark the wall. This locates the position for the top left attachment hole.

NOTE: Mark on wall MUST be in center of wood stud.

3. Align hole in top left corner of changing station with mark on wall and hold in place.

4. Using a level and measuring tape, mark the remaining three (3) holes. After marking holes, set changing station down on ground.

5. Use a power drill and appropriate bit to drill four (4) holes in the wall. This may require 2 people.

NOTE 1: For wood studs:

- If finished wall surface is tile or masonry over wood studs, use a 7/32” masonry bit for the pilot hole until you hit the wood stud, then change to 1/8” bit.

- Use wood screws, finishing washers and flat washers (Fig. a)

NOTE 2: For use with toggles:

- If finished wall surface has wood studs that are not 16” on center, has metal studs, or has an underlying surface of concrete block, use 1/2” bit.

- Use machine screws and flat washers (Fig. b).

- For holes NOT located in a wood stud, toggle anchors MUST be used (Fig. c). See “Using Toggle Anchors” section.

6. Align holes in changing station with drilled holes and secure top left corner of changing station to wall stud using the appropriate screw and washer. Continue to secure the three (3) remaining corners using the appropriate screws and washers as described in Note 1 or Note 2.

WARNING

All 4 of these locations MUST be used for safe installation. The lower holes ensure installation through the metal brackets.

Flat

Wood Stud

Washer

Finishing

 

 

Washer

 

 

Wood

 

 

Screw

 

Fig. a

Changing

Station

 

Wood Stud

Toggle

Anchor

Changing

 

Flat

 

Washer

Station

 

 

Machine

Fig. b Screw

Fig. c

7. Ensure all four (4) screws are tight and snap caps over screw heads.

Using Toggle Anchors:

1. Insert metal end of toggle anchor into 1/2” hole.

2. Slide zip strip down snugly against wall.

3. Snap off break-away pieces of toggle anchor (Fig. d).

4. Align holes in changing station with toggle anchors and secure top left corner of changing station to wall using machine screws and flat washers. Continue to secure the three (3) remaining corners using machine screws and flat washers.

5. Ensure all four (4) screws are tight and snap caps over screw heads.

2

Wood Stud

Toggle

Anchor

Break-Away

 

Fig. d

Page 3
Image 3
Foundations 100-EVBP manual Installation, Using Toggle Anchors

100-EVBP specifications

Foundations 100-EVBP stands out as a pivotal evolution in the realm of electric vehicle battery packs. Designed for both efficiency and sustainability, it showcases a culmination of advanced engineering and cutting-edge technology that addresses the challenges of modern mobility.

One of the foremost features of the Foundations 100-EVBP is its energy density, significantly higher than conventional batteries. By integrating next-generation lithium-ion cells, the Foundations 100-EVBP delivers exceptional performance, enabling longer ranges for electric vehicles. This breakthrough in energy storage is critical in eliminating range anxiety—a primary concern for potential EV users.

Another key characteristic of the Foundations 100-EVBP is its modular design. This allows for scalability and versatile applications across various vehicle platforms, from compact cars to larger electric SUVs and commercial vehicles. The modularity not only facilitates easier manufacturing but also simplifies maintenance and upgrades, providing longevity and adaptability as vehicle technologies evolve.

The thermal management system embedded within the Foundations 100-EVBP ensures optimal operating temperatures for the battery cells. By employing advanced cooling technologies, it mitigates the risks of overheating, which can degrade battery performance and lifespan. This system is designed to maintain efficiency under diverse environmental conditions, further enhancing the reliability of electric vehicles.

Safety is paramount in the Foundations 100-EVBP, which incorporates robust protective measures against short circuits, overcharging, and thermal runaway. The battery pack includes integrated smart sensors that continuously monitor cell health and performance, providing real-time data to vehicle systems. This proactive approach to safety guarantees not only the integrity of the battery but also the well-being of vehicle occupants.

Sustainability is a cornerstone of the Foundations 100-EVBP philosophy. The materials used are sourced responsibly, with a focus on reducing carbon footprints throughout the production process. Furthermore, the pack is designed for eventual recycling, ensuring that the lifecycle of the materials contributes to a circular economy.

The Foundations 100-EVBP represents a significant stride toward more sustainable and efficient electric transportation. Its innovative features, enhanced safety protocols, and commitment to environmental stewardship make it a compelling choice for manufacturers and consumers alike, promising a greener future for mobility.