Disassembly

MODEL : TOUCH & REMOTE CONTROL TYPE MODEL

1.

Remove the control box.

 

2.

Remove the screw which fasten control panel from

 

 

control box.

 

3.

Remove the screw which located in the front.

 

4.

Open the bottom side of control box.

 

5.

Remove the screw and the clamp which fastens

 

 

the capacitor.

 

6.

Disconnect all the leads of capacitor terminals.

 

7.

Re-install the components by referring to the

Figure 26

 

removal procedure, above. (See Figure 26)

7.POWER CORD

1.Remove the control box.

2.Open the control box.

3.Disconnect the grounding screw from the control box.

4.Disconnect the 2 receptacles.

5.Remove a screw which fastens the clip cord.

(See Figure 27)

6. Remove the power cord.

 

7. Re-install the component by referring to the above

 

removal procedure, above.

 

(Use only one ground-marked hole for ground

 

connection.)

 

8. If the supply cord of this appliance is damaged, it

Figure 27

must be replaced by the special cord. (The

 

special cord means the cord which has the same

 

specification marked on the supply cord attached at

 

the unit.)

 

Refrigerating Cycle

CAUTION: Discharge the refrigerant system using a FreonTM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system.

1.CONDENSER

1.Remove the cabinet.

2.Remove the 3 screws which fasten the

brace.

3. Remove the 3 screws which fasten the condenser and shroud.

4. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.

5. Remove the condenser carefully.

6. Re-install the component by referring to notes. (See Figure 28)

Figure 28

Service Manual 13

Page 13
Image 13
Friedrich CP12E10, CP10E10 manual Refrigerating Cycle, Model Touch & Remote Control Type Model