Disassembly
MODEL : TOUCH & REMOTE CONTROL TYPE MODEL
1. | Remove the control box. |
|
2. | Remove the screw which fasten control panel from |
|
| control box. |
|
3. | Remove the screw which located in the front. |
|
4. | Open the bottom side of control box. |
|
5. | Remove the screw and the clamp which fastens |
|
| the capacitor. |
|
6. | Disconnect all the leads of capacitor terminals. |
|
7. | Figure 26 | |
| removal procedure, above. (See Figure 26) |
7.POWER CORD
1.Remove the control box.
2.Open the control box.
3.Disconnect the grounding screw from the control box.
4.Disconnect the 2 receptacles.
5.Remove a screw which fastens the clip cord.
(See Figure 27)
6. Remove the power cord. |
|
7. |
|
removal procedure, above. |
|
(Use only one |
|
connection.) |
|
8. If the supply cord of this appliance is damaged, it | Figure 27 |
must be replaced by the special cord. (The |
|
special cord means the cord which has the same |
|
specification marked on the supply cord attached at |
|
the unit.) |
|
Refrigerating Cycle
CAUTION: Discharge the refrigerant system using a FreonTM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO
1.CONDENSER
1.Remove the cabinet.
2.Remove the 3 screws which fasten the
brace.
3. Remove the 3 screws which fasten the condenser and shroud.
4. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.
5. Remove the condenser carefully.
6.
Figure 28
Service Manual 13