Friedrich D50C, D65C, D30C, D40C manual OperatingInstructions, Control Panel

Models: D40C D65C D30C D50C

1 16
Download 16 pages 43.34 Kb
Page 11
Image 11
OperatingInstructions

OperatingInstructions

7 6

5 4 3

CONTROL PANEL

1.POWER key --- Pressing this key once turns the dehumidifier "ON" and pressing again turns the dehumidifier "OFF".

2.HUMIDITY CONTROL keys --- Are used to select the desired humidity setting.

A : Used to raise the desired humidity setting.

_ : Used to lower the desired humidity setting.

The desired humidity can be selected within a range of 35% to 70% RH in increments of 5%.

If you press the _ key once again at 35%RH, "On" mode is selected. In "On" mode the unit operates continuously, regardless of humidity conditions.

3.HUMIDITY SETTING display --- The desired humidity selected is displayed here.

4.FAN SPEED key --- Is used to set the fan speed as "High" or "Low".

Pressing this key changes the fan speed from High -_ Low -, High.

The selected fan speed is indicated by indicator lights marked "High" and "Low".

5.TIMER key --- It is used to select the type of operation.

Select either 2 or 4 hr. On/Off for cycled operation.

in this case the unit will run for 2 or 4 hours, and then shut off completely for 2 or 4 hours. The cycle will repeat until you change the setting.

When TIMER key is pressed, the TIMER indicator lights shift as 2hr.On/Off -, 4hr.On/Off -_Off.

6.BUCKET FULL Indicator --- This light glows when the bucket is full and needs to be emptied. It also

glows, when the bucket is not properly positioned. When bucket ful! indicator light glows, the compressor and fan wi!l turn "OFF".

7.AUTO RESTART --- Once the power is restored after a power outage, the unit begins to operate at its previous operation setting. The fan will run by default for 2 minutes. After 2 minutes both fan and compressor will be ON or OFF depending on the humidity conditions.

TO OPERATE THE DEHUMIDIFIER:

1.Plug the power cord into the electrical outlet. Press the POWER key.

2.Set the Humidity control between 35% to 70% for normal operation.

For less humidity, press the _ HUMIDITY CONTROL key.

For higher humidity, press the A HUMIDITY CONTROL key.

3.Press the TIMER key, to set the amount of time for which you want the unit to cycle On and Off. The time can be set for 2 hours or 4 hours.

4.If you want to change the fan speed, press the FAN SPEED key. Each time the FAN SPEED key is pressed the fan speed changes as High -, Low -, High.

5.Press the POWER key to stop the unit manually.

Water bucket must be properly installed.

The dehumidifier will not run if the bucket is not properly installed,

The dehumidifier shuts off when the desired humidity setting is reached.