Ductless Split Systems
Wall mounted, Tri-zone heat pump
Specifications
PERFORMANCE RATINGS
SYSTEM MODEL NO. |
| M27TYF | M30TYF | M33TYF | M36TYF1 | M36TYF2 | |||||
INDOOR MODEL |
| 3 x MW09Y3FM | 2 x MW09Y3FM |
| MW12Y3FM | MW09Y3FM | 2 x MW12Y3FM | 2 x MW09Y3FM |
| MW18Y3FM | 3 x MW12Y3FM |
OUTDOOR MODEL |
| MR36TQY3F | MR36TQY3F | MR36TQY3F | MR36TQY3F | MR36TQY3F | |||||
|
|
|
|
|
|
|
|
|
| ||
Capacity Cooling | Btu | 9200 ea. | 9300 ea. |
| 11800 | 9400 | 11800 ea. | 9100 ea. |
| 17000 | 11700 ea. |
Capacity Cooling Min - Max | Btu |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Sensible Heat Ratio |
| 0.71 | 0.71 |
| 0.71 | 0.71 | 0.71 | 0.71 |
| 0.71 | 0.71 |
Capacity Heating @ 47°F | Btu | 11200 ea. | 11000 ea. |
| 14000 | 10700 | 13600 ea. | 9800 ea. |
| 18400 | 12700 ea. |
Capacity Heating Min - Max | Btu |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Capacity Heating @ 17°F | Btu | 8300 ea. | 7700 ea. |
| 9800 | 7200 | 9200 ea. | 6700 ea. |
| 12500 | 8600 ea. |
HSPF |
| 9.0 | 9.0 | 9.0 |
| 9.0 |
| 9.0 | |||
|
|
|
|
|
|
| |||||
SEER |
| 15.0 | 15.0 | 15.0 | 15.0 | 15.0 | |||||
EER |
| 10.0 | 9.2 | 8.8 |
| 8.8 |
| 8.8 | |||
Moisture Removal | Pts/h | 2.9 ea. | 2.9 ea. |
| 3.7 | 2.9 | 3.7 ea. | 2.9 ea. |
| 5.7 | 3.7 ea. |
|
|
|
|
|
|
|
|
|
|
|
|
Airflow (Quiet, Low, Med, High) | CFM | 185,220,260,295 | 185,220,260,295 |
| 215,250,305,355 | 185,220,260,295 | 215,250,305,355 | 185,220,260,295 |
| 240,290,355,415 | 215,250,305,355 |
Sound Rating - Indoor | 27,29,33,37 | 27,29,33,37 |
| 30,34,39,42 | 27,29,33,37 | 30,34,39,42 | 27,29,33,37 |
| 33,39,42,46 | 30,34,39,42 | |
|
|
|
|
|
|
|
|
|
|
| |
Sound Rating - Outdoor | 52 | 52 | 52 |
| 52 |
| 52 | ||||
Operationg Range (heating) | °F | 0 - 115 (14 - 75) | 0 - 115 (14 - 75) | 0 - 115 (14 - 75) | 0 - 115 (14 - 75) | 0 - 115 (14 - 75) | |||||
Est. Yearly Operating Cost |
| $216 | $254 |
| $254 | $296 | $296 | $320 |
| $320 | $318 |
|
|
|
|
|
|
|
|
|
| ||
ELECTRICAL DATA (all indoor units receive power from outdoor unit; values listed are total) |
|
|
|
|
|
| |||||
Power Source |
| ||||||||||
|
|
|
|
|
|
| |||||
Min. Ampacity | A | 22.5 | 22.5 | 22.5 | 22.5 | 22.5 | |||||
Cooling Watts | W | 2710 | 3180 | 3710 | 4000 | 3980 | |||||
Max. TD Fuse/Breaker | A | 30 | 30 | 30 |
| 30 |
| 30 | |||
|
|
|
|
|
|
|
|
|
|
|
|
REFRIGERATION SYSTEM |
|
|
|
|
|
|
|
|
|
|
|
Refrigerant |
| R410A | R410A | R410A | R410A | R410A | |||||
|
|
|
|
|
|
| |||||
Compressor Type |
| Inverter | Inverter | Inverter | Inverter | Inverter | |||||
Connections |
| Flare | Flare | Flare | Flare | Flare | |||||
Liquid Line O.D. | in | 1/4" | 1/4" | 1/4" | 1/4" |
| 1/4" | 1/4" | |||
|
|
|
|
|
|
|
|
| |||
Suction Line O.D. | in | 3/8" | 3/8" | 3/8" | 3/8" |
| 1/2" | 3/8" | |||
Factory Precharge | ft | 165' | 165' | 165' | 165' | 165' | |||||
|
|
|
|
|
|
|
|
|
| ||
Max. Line Length | ft | Each unit:82 Total:230 | Each unit:82 | Total:230 | Each unit:82 | Total:230 | Each unit:82 | Total:230 | Each unit:82Total:230 | ||
Max. Height Difference | ft | 49' | 49' | 49' |
| 49' |
| 49' | |||
DIMENSIONS & WEIGHT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Indoor Unit |
|
|
|
|
|
|
|
|
|
|
|
W x H x D | in | 31 1/8" x 10 7/8" x 8 1/2" ea. | 31 1/8" x 10 7/8" x 8 1/2" ea. | 31 1/8" x 10 7/8" x 8 1/2" | 31 1/8" x 10 7/8" x 8 1/2" | 31 1/8" x 10 7/8" x 8 1/2" | |||||
|
|
|
|
|
|
|
|
|
| ||
Net Weight | lbs | 21 ea. | 21 ea. |
| 21 | 21 | 21 ea. | 21 ea. |
| 21 | 21 ea. |
Shipping Weight | lbs | 26 ea. | 26 ea. |
| 26 | 26 | 26 ea. | 26 ea. |
| 26 | 26 ea. |
Outdoor Unit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
W x H x D | in | 35 3/8" x 32 5/8" x 13" | 35 3/8" x 32 5/8" x 13" | 35 3/8" x 32 5/8" x 13" | 35 3/8" x 32 5/8" x 13" | 35 3/8" x 32 5/8" x 13" | |||||
Net Weight | lbs | 149 | 149 | 149 |
| 149 | 149 | ||||
|
|
|
|
|
|
|
| ||||
Shipping Weight | lbs | 167 | 167 | 167 |
| 167 | 167 |
NOTE: All models have low ambient capabilities
NOTE: All R410A models have 1/2˝ UNF 20 thread per inch charging and vacuuming ports. An adapter must be used for 1/4˝ gauges. Adapter part number 67270018 is available through Friedrich parts distributors.
Due to continuing research in new
Refrigeration line sets
USED WITH: | LIQUID | SUCTION | KIT# | ||
|
|
|
|
| |
All 9000 and | 15' | 1/4” | 3/8” | T32150 | |
12000 Btu |
|
|
|
| |
35' | 1/4” | 3/8” | T32350 | ||
indoor units | |||||
MW18Y3FM | 15' | 1/4” | 1/2” | T42150 | |
indoor units | 35' | 1/4” | 1/2” | T42350 |
Insulated line sets are available for all Friedrich split systems in 15 ft. and 35 ft. lengths. Each line set is equipped with flare nuts on both ends. Both liquid and suction lines are insulated. Line sets can be joined together with field supplied double female connectors. Each system requires one line set for each indoor unit installed. On
Ductless_Tri_Zone_Heat_Pump_Submittal_11