Friedrich MR24Y3H Specifications, Electrical Data, Fan Motor, Noise Level, Dimensions, Weight

Models: MR24Y3H MW18Y3H

1 29
Download 29 pages 20.89 Kb
Page 3
Image 3

SPECIFICATIONS

ELECTRICAL DATA

TYPE

 

 

 

Cool & heat inverter

 

 

 

 

 

 

 

INDOOR UNIT

 

MW18Y3H

MW24Y3H

 

 

 

 

 

OUTDOOR UNIT

 

MR18Y3H

MR24Y3H

 

 

 

 

 

 

 

COOLING CAPACITY

 

18,000 BTU/h

5.28 kW

22,000 BTU/h

6.50 kW

 

 

 

 

 

 

 

HEATING CAPACITY

 

21,600 BTU/h

6.30 kW

27,600 BTU/h

8.10 kW

 

 

 

 

 

POWER SOURCE

 

208 V / 230 V

208 V / 230 V

 

 

 

 

 

 

 

FREQUENCY

 

60 Hz

 

60 Hz

 

 

 

 

 

 

 

 

RUNNING CURRENT

 

Cooling

6.3 A

 

7.9 A

 

 

 

 

 

 

 

 

 

 

Heating

8.0 A

 

10.5 A

 

 

 

 

 

 

 

 

 

 

INPUT WATTS

 

Cooling

1.38 kW

1.76 kW

 

 

 

 

 

 

 

 

 

Heating

1.80 kW

2.38 kW

 

 

 

 

 

 

 

E.E.R.

Cooling

13.0 BTU/kW 3.83 kW/kW

12.5 BTU/kW 3.69 kW/kW

 

 

 

 

 

COP

Heating

12.0 BTU/kW 3.50 kW/kW

11.6 BTU/kW 3.40 kW/kW

 

 

 

 

 

 

 

MOISTURE REMOVAL

 

5.9 Pt/h

2.8 L/hr

6.3 Pt/h

3.0 L/hr

 

 

 

 

 

 

AIR CIRCULATION HIGH

541 cfm

920 m3/hr

659 cfm

1,120 m3/hr

 

 

 

 

 

 

 

MAXIMUM CURRENT

 

14.5 A

 

15.5 A

 

 

 

 

 

 

 

 

 

 

FAN MOTOR

POWER SOURCE

230 V

230 V

 

 

 

 

 

High speed

1,260 r.p.m.

1,480 r.p.m.

 

 

 

 

INDOOR UNIT

Middle speed

1,020 r.p.m.

1,220 r.p.m.

 

 

 

Low speed

900 r.p.m.

1,020 r.p.m.

 

 

 

 

 

 

Quiet

770 r.p.m.

900 r.p.m.

 

 

 

 

OUTDOOR UNIT

Cool

620 r.p.m.

800 r.p.m.

 

 

 

Heat

620 r.p.m.

850 r.p.m.

 

 

 

 

 

NOISE LEVEL

INDOOR UNIT

Cool 43 dB

/

Heat 44 dB

Cool 49 dB

/

Heat 49 dB

 

 

 

 

 

 

 

OUTDOOR UNIT

Cool 47 dB

/

Heat 50 dB

Cool 54 dB

/

Heat 55 dB

 

 

 

 

 

 

 

COMPRESSOR AND REFRIGERANT

TYPE

 

 

Hermetic type, 6 pole, DC inverter motor, Rotary

 

 

 

 

DISCRIMINATION

 

 

N-TF30ND1A

WEIGHT WITH OIL

 

 

34.2 lb

15.5 kg

 

 

 

 

PRECHARGED REFRIGERANT

4 lb 10 oz

2,100 g

 

 

 

 

REFRIGERANT TYPE

 

R410A

 

 

 

 

 

Pipe length

66 ft

20 m

4 lb 10 oz

2,100 g

FULL CHARGE

 

 

 

 

164 ft

50 m

7 lb 4 oz

3,300 g

 

 

 

 

 

ADDITIONAL CHARGE

 

0.43 oz/ft

40 g/m

 

 

 

 

 

DIMENSIONS

INDOOR UNIT

H x W x D

12-5/8 x 39-1/4 x 9 inch

320 x 998 x 228 mm

 

 

 

 

OUTDOOR UNIT

H x W x D

32-3/4 x 35-3/8 x 13 inch

830 x 900 x 330 mm

 

 

 

 

WEIGHT

INDOOR UNIT

Shipping / Net

40 lbs / 31 lbs

18 kg / 14 kg

 

 

 

 

OUTDOOR UNIT

Shipping / Net

150 lbs / 135 lbs

68 kg / 61 kg

 

 

 

 