Control Panel Operation

Control Panel Operation

Dehumidifying and cooling operation

The operating range for cooling operation is 63°F - 88°F (or 17°C - 31°C) and the operating range for dehumidifying is 68°F - 88°F (or 20°C - 31°C).

Power source

The AC socket must be firm and reliable.

Don’t connect the portable air conditioner to a multiple socket outlet which is also being used for other electrical appliances.

Insert the AC power plug securely into the AC socket before using the unit, when it beeps after two seconds, press ON/ OFF button, the unit begins to run.

LCDI power cord information

All Friedrich portable air conditioners are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI device meets the UL and NEC requirements for cord connected air conditioners effective Au- gust 2004.

To test your power supply cord:

1.Plug power supply cord into a grounded 3 prong outlet.

2.Press RESET (See drawing below).

3.Press TEST (listen for click; Reset button trips and pops out).

4.Press and release RESET (listen for click; Reset button latches and remains on). The power supply cord is ready for operation.

NOTE: LCDI device is not intended to be used as a switch.

Once plugged in the unit will operate normally without the need to reset the LCDI device.

If the device fails to trip when tested or if the power supply cord is damaged it must be replaced with a new supply cord from the manufacturer. We recommend you contact our Technical Assis- tance Line at (800) 541-6645. To expedite service, please have your model and serial number available.

RESET

TEST

 

Test Button

 

Reset Button

WARNING: NEVER CUT OR REMOVE THE GROUNDING PRONG FROM PLUG. NEVER USE EXTENSION CORDS TO OPERATE AN AIR CONDITIONER.

Cooling operation

1.Press MODE button to choose the cooling mode, LCD window will show “cool”.

During the cooling operation, always place the air exhaust hose through an open window.

2.Repeatedly press TEMP+ or TEMP- button to set a proper room TEMP. between 63°F - 88°F.

3.Press FAN SPEED button to choose a proper fan speed: high, middle, low speed.

4.Press SWING button to adjust the air delivery direction, The LCD window will show “ Dehumidifying and cooling operation ”.

NOTE:

In order to improve the cooling efficiency:

a)If your room is directly exposed to the sun, draw the cur- tains.

b)Do not place near other heat source.

Dehumidifying Operation

1.Keep the windows and the doors closed to aid in effectively dehumidifying the room.

2.Press MODE button to choose the dehumidifying mode, LCD window will show “DRY”, the fan speed cannot be adjusted.

When used as dehumidifier only it is not necessary to install the exhaust hose.

Time Set Function

To set the time to start the machine, with the unit off (but pow- er supplied), press TIMER button, the LCD window will show

Power sourceLCDI power cord information”, continually press the TIMER button, set the preferred start time. The setting range is 1-12 hours.

To set the time to stop the machine, with the unit running, press

TIMER button, the LCD window will show “Cooling operationDehumidifying Operation”, continually press the TIMER button ,set the preferred time to stop the ma- chine. The setting range is 1-12 hours

NOTE: During timer mode, if the TIMER button is pressed again, it will cancel the timer operation.