Friedrich P/N9368987060-01 Temperature Set Back Timer, En-8, Temperature SET BACK timer setting

Models: P/N9368987060-01

1 18
Download 18 pages 38.77 Kb
Page 9
Image 9
TEMPERATURE SET BACK TIMER

TEMPERATURE SET BACK TIMER

Temperature SET BACK timer setting

1

SET BACK

SU MO TU WE TH FR SA

3 6 9 12 15 18 21 Temperature SET BACK timer setting

Press the SET BACK button to change to the SET BACK con- firmation display.

The SET BACK operating time and the set temperature will be displayed.

If there is no existing SET BACK tempera- ture setting, “- -” will be displayed for the temperature.

2SET BACK SET

Press the SET button for 2 seconds or more.

3

Day setting

 

Operating time setting

 

 

 

 

 

 

 

 

 

SU MO TU

WE TH FR SA

 

DAY

SET

SET

 

 

 

 

 

 

DAY OFF

 

 

 

3

6

9

12 15 18 21

 

2

 

4

ex. When setting all days together

 

1

3

Follow the same procedures to set the operating time as those for the weekly timer. The DELETE button is also used as described in the procedures for the weekly timer.

4

Temperature setting

Press the SET TEMPERATURE buttons to

 

set the temperature (from 64 °F to 88 °F).

 

 

SU MO TU WE TH FR SA

 

 

 

 

3

6

9

12 15 18 21

SET BACK

ON

84°F

OFF

ex. Operating time 3:00–10:00 P.M.

temperature

76°F

 

 

(15:00–22:00)

Normal

 

 

76°F

 

 

 

temperature

 

 

 

 

 

 

 

5

DAY OFF SET

Repeat steps 3 and 4. Press the SET button for 2 seconds or more to com- plete the temperature SET BACK timer settings.

Temperature SET BACK timer operation

To start

SET BACK

SU MO TU WE TH FR SA

ex. Display during SET BACK timer operation (The operating time will not be displayed.)

Press the SET BACK button. The SET BACK confirmation display appears for 5 seconds, and then the timer starts automatically.

To cancel

SET BACK

DELETE

1

2

Press the SET BACK button, and then press the DELETE button while the SET BACK confirmation display is dis- played. Even if the SET BACK button is pressed again, the SET BACK timer will be cancelled.

NOTES

(1)The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner operation.

(2)The SET BACK timer can be set to operate up to two times per day but only one temperature setting can be used.

(3)The SET BACK timer can be used together with the ON, OFF, and weekly timer functions.

(4)The SET BACK operating time is displayed only in the SET BACK confirmation display. (Refer to step 1 for the SET BACK confirmation display.)

(5)The SET BACK operating time is displayed only in the SET BACK confirmation display. (Refer to step 1 for the SET BACK confirmation display.)

En-8

9368987060-01_OM_en.p65

8

2/4/10, 4:45 PM

Page 9
Image 9
Friedrich P/N9368987060-01 manual Temperature Set Back Timer, En-8, Temperature SET BACK timer setting, 2SET, Day Off