CONDENSATION HANDLING
Your ZoneAire® Portable Air Conditioner is designed to evaporate the condensation removed from the interior space through the exhaust hose. Under certain conditions it is possible that the unit will not evaporate 100% of the removed moisture.
The unit is designed with a
Internal Water Level
1.Under any mode if the water level is in the “low” area the unit will function normally.
2.If the water level is in the “normal” area the unit will continue to function normally while internally evaporating the condensate.
3.If the unit cannot evaporate all of the condensate internally, the tank may become full. If the tank becomes full, the unit will turn off, and the Water Full light will illuminate.
Draining Water
The water can be drained from the unit by removing the base stopper and letting the water drain by gravity.
1.When the WATER FULL lamp is on unplug the unit and move the unit to a suitable location for draining the condensation.
2.Using the gravity drain method, ensure that the base stopper is located above a suitable area for draining the condensate and remove the stopper.
3.Return the unit to the original location and restore power and duct connections.
4.The WATER FULL indicator should be off and the unit will return to normal operating mode.
Permanent Drainage
For permanent and continuous drainage, a 1/2" hose may be attached to the unit and led down a drain.
Drain Valve