Specifications
Input:
•Voltage:
Output:
•Maximum: 1 amp per terminal (3 amp total for all terminals)
Temperature Ranges:
• | Temperature control range: 45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.5°C) |
• | Differential range: 1°F to 3°F (0.5°C to 1.5°C) Accuracy: ± 1°F (± 0.5°C) |
•System configurations: Single stage heat pump
• Terminations: R, C, W, Y, B, O, G
• Note: This thermostat is designed for: Single stage electric heating, heating/cooling systems and heat pump systems. It will retain your setpoint temperatures in memory for up to 30 minutes during a power outage.
SET ROOM
DIFF
Important Safety Information
•Always turn off the thermostat before installing, removing, cleaning, or servicing; turn off the power at the main power source by unscrewing fuse or switching off circuit breaker
•Do not switch to “Cool” if outside temperature is below 50°F (10°C), this could damage your A/C system and cause injury
•Do not install on voltages higher than 30 VAC
•All wiring must conform to local and national building and electrical codes and ordinances
•While cleaning, do not get soap directly on thermostat switches or LCD readout; only use a damp cloth with a mild soap to wipe the outside of the thermostat cover
2