Friedrich WMPTAC02 manual PTAC Model Number Identification Guide, Notes & Comments

Models: WMPTAC02

1 12
Download 12 pages 16.01 Kb
Page 3
Image 3
PTAC Model Number Identification Guide

PTAC Model Number Identification Guide

Model Number

 

T

H

C

07

K

25

ST

C

Series

 

 

 

 

 

 

 

 

 

Engineering Code

T = T Series

 

 

 

 

 

 

 

 

 

A - B - C

Unit Type

 

 

 

 

 

 

 

 

Option

E = Electric Heat/No Heat

 

 

 

 

 

 

 

 

ST = Standard Unit

H = Heat Pump

 

 

 

 

 

 

 

 

RT = Remote Thermostat

Design Series

 

 

 

 

 

 

 

 

DC = Central Desk Control

C = Friedrich Manufactured

 

 

 

 

 

 

 

 

SP = Seacoast Protection

A & B = ICP Manufactured

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal Heater Size

 

 

 

 

 

 

 

 

Nominal Cooling Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(@ 230V or 265V)

07 = 6,500 - 7,200 BTUh

12 = 11,500 - 12,200 BTUh

 

00 = No electric heater

09 = 8,500 - 9,200 BTUh

15 = 14,000 - 15,000 BTUh

 

25 = 2.5 KW

 

 

 

 

 

 

 

 

34 = 3.4 KW

Voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 = 5.0 KW

K = 208/230V - 1PH - 60Hz

R = 265V - 1PH - 60Hz

 

 

 

PTAC Serial Number Identification Guide

 

Serial Number

 

 

JG

 

A

P

00000

 

 

 

 

 

 

 

 

 

Production Run Number

 

Year Manufactured

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = 1

D = 4

G = 7

K = 0

 

 

Manufacturing Location

 

B = 2

E = 5

H = 8

 

 

 

 

C = 3

F = 6

J = 9

 

 

 

 

S = San Antonio

 

Month Manufactured

 

 

 

 

 

P = San Antonio

 

A = Jan

D = Apr

G = Jul

K = Oct

 

 

 

 

B = Feb

E = May

H = Aug

L = Nov

 

 

 

 

C = Mar

F = Jun

J = Sep

M = Dec

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes & Comments

Note

 

Units Affected

Note or Comment

 

Heat Pump

 

All

Identifies the parts or components used specifically in the heat

 

 

THC units

pump units. All other components are consistent with all other

 

 

 

units.

 

 

 

 

Note 1

 

A, B & C suffix

Identifies the parts or components used specifically in units built

 

 

prior to August 1997 (serial prefix JGHP.....)

 

 

 

 

 

 

 

Note 2

 

All

Identifies the parts or components used specifically in units built

 

 

C suffix only

starting September 1997 (serial prefix JGJP.....) to current.

 

 

 

 

Note 3

 

All

The thermostat was changed from the original that had a short

A & B

 

suffix only

3/8” diameter bulb to the thermostat that has a long 1/4” bulb.

 

 

 

Both have the same operating range. If changing from the 3/8”

 

 

 

bulb this kit is required.

 

 

 

 

265V

 

All

Identifies the parts or components used specifically in units built

 

 

Voltage code R

to operate on 265V 1PH 60Hz (same as 277V 1PH 60Hz)

 

 

 

 

3

Page 3
Image 3
Friedrich WMPTAC02 manual PTAC Model Number Identification Guide, PTAC Serial Number Identification Guide, Notes & Comments