MICROWAVE/ WALL OVEN COMBINATION

INSTALLATION INSTRUCTIONS

Important Notes to the Installer

1.Read all instructions contained in these installation instructions before installing the combination oven.

2.Remove all packing material from the oven compartments before connecting the electrical supply to the wall oven.

3.Observe all governing codes and ordinances.

4.Be sure to leave these instructions with the consumer.

5.Oven door may be removed to facilitate installation.

6.THIS COMBINATION OVEN IS NOT APPROVED FOR STACKABLE OR SIDE-BY-SIDE INSTALLATION.

Important Note to the Consumer

Keep these instructions with your Owner's Guide for future reference. Do not discard oven removal tools found in the literature bag.

IMPORTANT SAFETY

INSTRUCTIONS

Be sure your combination oven is installed and grounded properly by a qualified installer or service technician.

This wall oven must be electrically grounded in accordance with local codes or, in their absence, with the National Electrical Code ANSI/NFPA No.70- latest edition in United Sates, or with CSA Standard C22.1, Canadian Electrical Code, Part 1, in Canada.

Stepping, leaning or sitting on the door of this wall oven can result in serious injuries and can also cause damage to the wall oven.

Never use your wall oven for warming or heating the room. Prolonged use of the wall oven without adequate ventilation can be dangerous.

The electrical power to the oven must be shut off while line connections are being made. Failure to do so could result in serious injury or death.

1. Carpentry

Refer to figure 1 for the dimensions applicable to your appliance, and the space necessary to receive the combination oven. The oven support surface may be solid plywood or similar material, however the surface must be leveled from side to side and from front to rear.

2. Electrical Requirements

This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse. To know the circuit breaker or fuse required by your model, see the serial plate to find the wattage consumption and refer to table A to get the circuit breaker or fuse amperage.

Appliance

Protection

Appliance

Protection

Rating Watts

Circuit

Rating Watts

Circuit

240V

Recommended

208V

Recommended

 

 

 

 

Less than 4800W

20A

Less than 4100W

20A

 

 

 

 

4800W - 7200W

30A

4100W - 6200W

30A

 

 

 

 

7200W - 9600W

40A

6200W - 8300W

40A

 

 

 

 

9600W and +

50A

8300W and +

50A

 

 

 

 

Table A

Observe all governing codes and local ordinances

1.A 3-wire or 4-wire single phase 120/240 or 120/208 Volt, 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line (red and black wires). A time-delay fuse or circuit breaker is recommended. DO NOT fuse neutral (white wire). Only certain cooktop models may be installed over certain built-in electric oven models. Approved cooktops and built-in ovens are listed by the MFG ID number (see the insert sheet included in the literature package).

NOTE: Wire sizes and connections must conform with the fuse size and rating of the appliance in accordance with the American National Electrical Code ANSI/NFPA No. 70-latest edition, or with Canadian CSA Standard C22.1, Canadian Electrical Code, Part 1, and local codes and ordinances.

An extension cord should not be used with this appliance. Such use may result in a fire, electrical shock, or other personal injury. If you need a longer power cord you can purchase a 10' (3 m) power cord kit #903056-9010 by calling the Service Center.

2.These appliances should be connected to the fused disconnect (or circuit breaker) box through flexible armored or nonmetallic sheathed cable. The flexible armored cable extending from the appliance should be connected directly to the junction box. The junction box should be located as shown in Figure 1 or Figure 2 and with as much slack as possible remaining in the cable between the box and the appliance, so it can be moved if servicing is ever necessary.

3.A suitable strain relief must be provided to attach the flexible armored cable to the junction box.