Frigidaire FGGC3645KB, FGGC3645KS Drop-InCooktop Specifications, Optional Accessories, Frigidaire

Models: FGGC3645K FGGC3645KB FGGC3645KW FGGC3645KS

1 3
Download 3 pages 231 b
Page 2
Image 2
Drop-In Cooktops

Drop-In Cooktops

FGGC3645K S / W/B 36" Gas

Overall Product Dimensions

Product Cutout Dimensions

G - Cabinet

Power Supply

Gas Supply

 

 

 

 

 

 

Opening

Connection

Connection

A – Width

B - Depth

C - Height

D - Width

E - Depth

F - Height*

Width

Location

Location

 

 

 

 

 

 

 

 

 

36"

21-3/4"

5"

33-7/8" min.

19-1/8" min.

8" min.

36" min.

Right Rear

Right Rear

34-1/4" max.

19-3/4" max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drop-In Cooktop Specifications

Product Shipping Weight (approx.) – 60 Lbs.

Voltage Rating – 120V / 60 Hz / 15 Amps

For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.

Amps @ 120 Volts = 1.0 Amps

Always consult local and national electric and gas codes.

Recommended location for grounded 120V outlet is on rear wall in an 8" wide by 10" high area, positioned 22" above floor surface and 4" from right side of cooktop centerline. Access to underside of cooktop and junction box must be provided for inspection and service.

Cooktop ships with 3/4" factory regulator.

LP Gas conversion kit supplied.

Overhead cabinetry should not exceed a 13" maximum depth.

Allow 30" minimum clearance between top of cooktop and bottom of unprotected wood or metal overhead cabinetry.

Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than 36".

Allow 24" minimum clearance when bottom of wood or metal overhead cabinet is protected by not less than 1/8" flame-retardant millboard covered with not less than No. 28 MGS sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.

Allow 2-1/2" minimum distance between rear edge of cutout and nearest combustible surface above countertop.

Allow 7" minimum clearance from edge of cooktop to nearest combustible wall on either side of unit.

Installation of drawers beneath cooktop requires minimum 8" clearance beneath countertop surface and assured clearance for gas and electrical connections.

To reduce risk of fire when using overhead cabinetry, install range hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets.

Gas Drop-In Cooktop model FGGC3645KS is approved to be used over any Frigidaire® Electric Single Wall Oven, models FGGC3645KW and FGGC3645KB are NOT approved for this installation. (Refer to Gas Cooktop Installation Over 30" / 27" Electric Single Wall Oven Specifications page on web.)

Gas Drop-In Cooktop model FGGC3645K is approved to be used in combination with any Frigidaire® 36" Downdraft Vent. (Refer to model-specific Downdraft Vent product page on web for detailed countertop preparation specifications.)

Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

Optional Accessories

Granite Countertop Installation Kit – (PN # 903103-9010).

FRIGIDAIRE

USA Electrolux Major Appliances, North America 250 Bobby Jones Expressway Martinez, GA 30907 1-800-FRIGIDAIRE frigidaire.com

Specifications

CANADA Electrolux Canada Corporation 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca

subject to change.

FGGC3645K 04/09

© 2009 Electrolux Home Products, Inc.

Printed in the U.S.A.