Frigidaire FHWC3640MS Overhead Hood, Under-CabinetHood Specifications, Optional Accessories

Models: FHWC3640MS

1 2
Download 2 pages 24.74 Kb
Page 2
Image 2
Overhead Hood

Overhead Hood

FHWC3640MS 36" Under-Cabinet

Under-Cabinet Hood Specifications

Product Shipping Weight (Approx.) – 27 Lbs.

Under-Cabinet Installation – can be ducted vertically or horizontally.

Ventilation system can exhaust air outside, either vertically through roof or horizontally through wall. (Refer to Ducting Option Specifications for outside ventilation.). If ducting outside is not possible, the system can be alternately set to recirculate air inside, requiring use of recirculating kit, included with hood.

Sones Rating – 7.7

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = .23 kW

(For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.)

Amps @ 120 Volts = 1.8 Amps

Always consult local and national electric codes. Check local building codes for installation requirements, as they may vary per locale.

Makeup air systems may be required by local building codes when using ventilation systems greater than specified CFM of air movement. Specified CFM varies per locale.

Connect vent hood with copper wire only. (For installation pre-wired with aluminum wiring, refer to Product Installation Guide on web for correct wiring procedure.)

Locate vent hood away from strong draft areas, such as windows, doors or strong heating vents.

Minimum 24" - 30" installation height allowed from bottom of hood canopy to cooking surface; minimum 66" height suggested from top of hood to floor.

When installing vent hood under cabinets with recessed bottoms, two 2"-wide filler strips required with length and thickness determined by recess dimensions.

Ducting Option Specifications

Vent system MUST terminate outside through roof or wall; do NOT terminate into attic or other enclosed area.

Exhaust Duct Required – 3-1/4" x 10" rectangular with 35' maximum vent length or 7" round with 50' maximum vent length. Refer

to Product Installation Guide on web for calculations needed to determine total duct length.

Installation of 7" Round Duct requires use of 7" Round Transition Duct (included) and can only be vented vertically.

To provide efficient performance, length of vent system and number of elbows should be kept to minimum. Flexible vent greatly reduces performance and is NOT recommended.

Use 3-1/4" x 10" rectangular metal vent only – rigid metal vent recommended; plastic or metal foil vent NOT recommended.

For cold weather installation, additional backdraft damper and thermal break should be installed. Thermal break will minimize conduction of outside temperatures as part of the vent system with damper on cold air side of break, as close as possible to where vent system enters heated portion of house.

Refer to Product Installation Guide on web for detailed vent system preparation instructions.

Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

Optional Accessories

Charcoal Filter – (PN # 5304486303).

Duct-Free Kit (Single-Pack) – (PN # 5304455850).

Duct-Free Kit (8-Pack) – (PN # DFKIT368PK).

Damper Kit (6-Pack) – (PN # DAMPKIT6PK).

7"-Round Damper Kit (Single-Pack) – (PN # 5304455851).

 

Accessories information available on the web at frigidaire.com

 

 

USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com

Specifications

CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca

subject to change.

FHWC3640M 08/14