Operating Instructions

 

 

 

 

 

 

 

 

 

Operating Instructions

 

 

(continued)

 

 

TO USE THE ENERGY SAVER

YOU WILL SEE:

FEATURE:

 

 

DO THIS:

PRESS

MODE BUTTON

CHOOSE

ENERGY SAVER

Note: In this mode, the fan will continue to run for 1 minute after the compressor shuts off. The fan then cycles on for 20 seconds at 10 minute intervals until the room temperature is above the set temperature, at which time the compressor turns back on.

TIMER: DELAY STOP / START FEATURE

YOU WILL SEE HOW MUCH TIME IS CHOSEN:

FIRST

DO THIS:

PRESS TIMER BUTTON

THEN

DO THIS:

PRESS

UP/DOWN

SET BUTTONS

Note: For Delay Stop, the unit must be in the On position.

Note: For Delay Start, the unit must be in the Off position.

First, Press TIMER button, then adjust timer setting, tap or hold the UP arrow ( ) or the DOWN arrow ( ) to change delay timer at 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start (8, 7.5, 7, etc.). The Delay Start Operation automatically selects cooling with maximum Fan speed (if Cool, Energy Saver, or Fan Only was the last mode selected) or heating with maximum Fan speed (if Heat was the last mode selected. Note: On 115V models only low speed can be selected.) The temperature maintained will be the same as previously set. To change the set temperature, press "COOL" then Up or Down arrows until the desired temperature is indicated on the display. After 5 seconds, the control will automatically change the display back to the hours remaining until the unit will start/stop. Pressing the unit On/Off button at any time will cancel the Delay Start/Stop function. The Delay Start/Stop Feature will work until the unit either starts or stops. Once that happens the above steps have to be repeated again.

SLEEP FEATURE:

YOU WILL SEE:

DO THIS:

PRESS

SLEEP BUTTON

Note: In this mode the selected temperature will increase by 2 °F 30 minutes after the mode is selected. The temperature will then increase by another 2 °F after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the "Sleep" mode and the unit will continue to operate as originally programmed. The "Sleep" mode program can be cancelled at any time during operation by again pressing the "Sleep" button.

2009 Electrolux Home Products, Inc.

All rights reserved.

7

 

 

 

 

 

 

Page 7
Image 7
Frigidaire FRA124HT2, FRA14EHT2, FRA08EHT1, FRA12EHT2, FRA106HT1 To USE the Energy Saver YOU will see Feature, Sleep Feature

FRA106HT1, FRA12EHT2, FRA14EHT2, FRA086HT1, FRA106HT2 specifications

The Frigidaire FRA series of air conditioners, including models FRA08EHT1, FRA124HT2, FRA106HT2, FRA144HT2, and FRA086HT1, provide effective cooling solutions for various room sizes while offering a range of features aimed at enhancing user experience and comfort.

The FRA08EHT1 is designed for smaller spaces, with a cooling capacity of 8,000 BTUs. It features a compact design and is suitable for rooms up to 350 square feet. Its Energy Saver mode helps in reducing electricity costs by limiting compressor run time while its programmable timer allows users to set the unit to turn on or off at specified times.

Stepping up in capacity, the FRA124HT2 offers 12,000 BTUs of cooling power, making it suitable for rooms up to 550 square feet. This model includes both cooling and heating capabilities, providing year-round comfort. Its multi-speed fan allows users to customize airflow while the built-in air ionizer improves indoor air quality by reducing airborne particles.

The FRA106HT2 is similar to the FRA124HT2 in performance, providing 10,000 BTUs of cooling for medium-sized rooms. It offers quiet operation, thanks in part to its sound-dampening features, making it ideal for bedrooms or home offices. The adjustable airflow direction ensures effective cooling distribution, and its remote control adds convenience for adjusting settings from a distance.

For larger spaces, the FRA144HT2 stands out with its robust 14,000 BTU cooling capacity. It is capable of cooling areas up to 700 square feet, making it suitable for living rooms or open floor plans. This model features advanced temperature controls and a digital display that allows users to monitor and adjust settings easily. The energy-efficient design helps keep operating costs low.

Lastly, the FRA086HT1 is another versatile option, providing 8,000 BTUs and combining both cooling and heating functions. Its compact size caters to smaller to medium rooms while offering the benefit of an adjustable thermostat and easy-to-use controls.

All models in the Frigidaire FRA series prioritize energy efficiency, ensuring users benefit from effective cooling while minimizing environmental impact. With features like a washable filter for easy maintenance and user-friendly controls, these air conditioners are designed to meet diverse needs while providing a comfortable and refreshing indoor environment.