Frigidaire HEAVY DUTY AIR CONDITIONER manual Occurrence Solution

Models: HEAVY DUTY AIR CONDITIONER

1 12
Download 12 pages 34.72 Kb
Page 12
Image 12

Avoid Service Checklist Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the

result of defective workman- ship or materials in this appliance.

 

OCCURRENCE

SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

Air conditioner will not operate.

 

Wall plug disconnected. Push plug firmly into wall outlet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Plug Current Device Tripped. Press the RESET button.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or

 

 

 

 

 

 

 

reset circuit breaker.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Control is OFF. Turn Control ON and set to desired FAN or COOL setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit turned off and then on too quickly, wait 3 minutes before compressor will

 

 

 

 

 

 

 

automatically restart.

 

 

 

 

 

 

 

 

 

 

 

 

Air from unit does not feel cold

 

Room temperature below 60°F (16°C). Cooling may not occur until room temperature

 

 

 

rises above 60°F (16°C).

 

 

enough.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature sensor touching cold coil,located behind air filter.Straighten away from

 

 

 

 

 

 

 

coil.

 

 

 

 

 

 

 

Reset to a Lower temperature.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor shut-off by changing modes. Wait approximately 3 minutes, and listen

 

 

 

 

 

 

 

for compressor to restart when set in the COOL modes.

 

 

 

 

 

 

 

 

 

 

 

 

Air conditioner cooling, but room

 

Outdoor temperature below 60°F (16°C). To defrost the coil, set selector to FAN

 

 

 

ONLY Mode.

 

 

is too warm ice forming on cooling

 

 

 

 

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set

 

 

 

 

 

coil behind decorative front.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

selector to FAN ONLY Mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature is set too Low for night-time cooling. To defrost the coil, set to FAN

 

 

 

 

 

 

 

ONLY Mode. Then, set Temperature to a Higher number.

 

 

 

 

 

 

 

 

 

 

 

Air conditioner cooling, but room

 

Dirty air filter air restricted. Clean air filter. Refer to Care and Cleaning section.

 

 

 

 

 

 

 

 

 

 

is too warm NO ice forming on

 

Temperature is set too High. Set temperature to a Lower number.

 

 

 

cooling coil behind decorative

 

 

 

 

 

 

 

 

Air directional louvers positioned improperly. Position louvers for better air

 

 

 

front.

 

 

 

 

 

distribution.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front of unit is blocked by drapes, blinds, furniture, etc. restricts air distribution.

 

 

 

 

 

 

 

Clear blockage in front of unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Doors, windows, registers, etc. open cold air escapes. Close doors, windows,

 

 

 

 

 

 

 

registers, etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit recently turned on in hot room. Allow additional time to remove “stored heat”

 

 

 

 

 

 

 

from walls, ceiling, floor and furniture.

 

 

 

 

Air conditioner turns on and off

 

Dirty air filter air restricted. Clean air filter.

 

 

 

 

rapidly.

 

 

 

 

 

 

 

 

Outside temperature extremely hot. Set FAN speed to a faster setting to bring air past

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cooling coils more frequently.

 

 

 

 

 

 

 

 

 

 

 

 

Noise when unit is cooling.

 

Air movement sound. This is normal. If too loud, set to a slower FAN setting.

 

 

 

 

 

 

 

 

Sound of fan hitting water-moisture removal system. This is normal when humidity is

 

 

 

 

 

 

 

high. Close doors, windows and registers.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Window vibration poor installation. Refer to installation instructions or check with

 

 

 

 

 

 

 

installer.

 

 

 

 

 

 

 

 

 

 

 

Water dripping INSIDE when unit

 

Improper installation. Tilt air conditioner slightly to the outside to allow water

 

 

 

is cooling.

 

drainage. Refer to installation instructions check with installer.

 

 

 

 

Water dripping OUTSIDE when

 

Unit removing large quantity of moisture from humid room. This is normal during

 

 

 

 

unit is cooling.

 

excessively humid days.

 

 

 

 

 

 

 

 

 

 

 

Room too cold

 

Setting too low. Increase temperature setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote sensing activated (on some models) and remote control located in Hot Spot-

 

 

 

 

 

 

 

Relocate remote control or deactivate remote sensing.

 

 

 

 

Remote sensing deactivating

 

Remote control not located within range. Place remote control within 20 feet &

 

 

 

 

 

 

 

 

 

 

 

Prematurely (some models).

 

140º,Radius of the front of the unit. Remote control obstructed. Remove obstruction.

 

 

 

 

 

 

 

 

 

 

 

 

If These Solution Fail, Call 1-800-444-4944 For Frigidaire Service.

12

Page 12
Image 12
Frigidaire HEAVY DUTY AIR CONDITIONER manual Occurrence Solution

HEAVY DUTY AIR CONDITIONER specifications

The Frigidaire Heavy Duty Air Conditioner stands out as a reliable solution for both residential and commercial cooling needs. Designed with efficiency and performance in mind, this air conditioning unit promises to deliver a refreshing indoor environment even during the hottest months of the year.

One of the main features of the Frigidaire Heavy Duty Air Conditioner is its powerful cooling capacity. With BTU ratings that cater to various room sizes, this unit can effectively cool spaces ranging from small bedrooms to large living areas. The heavy-duty compressor ensures optimal performance even during periods of high demand, making it ideal for environments where consistent cooling is crucial.

Incorporating advanced technologies, the Frigidaire Heavy Duty Air Conditioner boasts an energy-efficient design, which is highlighted by its Energy Efficiency Ratio (EER) ratings. These ratings indicate the unit's capability to deliver cooling with minimal energy consumption, promoting cost savings on electricity bills while being environmentally conscious. This eco-friendly approach is further enhanced by the use of R-410A refrigerant, which is known to have less impact on the ozone layer compared to older refrigerants.

The unit is equipped with a digital thermostat that allows users to set the desired temperature with precision. This feature, combined with multiple cooling speeds and fan settings, provides enhanced flexibility to cater to different preferences. The programmable timer is another convenient addition, enabling users to schedule the operation of the air conditioner according to their daily routines.

Durability is another hallmark of the Frigidaire Heavy Duty Air Conditioner. Constructed with robust materials, the unit can withstand harsh environmental conditions, ensuring long-lasting performance. The corrosion-resistant exterior protects the internal components, enhancing longevity and minimizing maintenance needs.

For added convenience, the Frigidaire Heavy Duty Air Conditioner features a user-friendly remote control, allowing adjustments from a distance. Additionally, the unit comes with a washable, reusable air filter that not only improves indoor air quality but also simplifies maintenance tasks.

In summary, the Frigidaire Heavy Duty Air Conditioner is a powerful, efficient, and durable cooling solution. With its robust features, advanced technologies, and user-friendly design, this air conditioning unit is well-suited for those seeking comfort and reliability in their cooling systems. Whether for residential or commercial use, it provides an excellent balance of performance, efficiency, and durability.