For G6 & L1 Series Furnaces

Designed for Canadian installations. To convert a natural gas
furnace to LP/Propane gas for altitudes between 0 to 4,500
feet above sea level, the main gas orifice must be replaced.
For higher altitudes (between 2,000 & 4,500 feet above seal
level) the input must be de-rated by 10%. This can be done
by simply reducing the manifold pressure without changing
the gas orifices.
Use on standard & slow opening models only
Not for use with step regulator valves
Application Brand Part
Number
For use with G6 & L1 series gas furnaces using a
Honeywell Gas Valve Frigidaire 904091A

For G7 Series Furnaces

Designed for Canadian installations to convert a natural gas
furnace to LP/Propane gas. Used for altitudes between 0 to
4,500 feet above sea level
For altitudes between 0 and 1,999 feet, only the orifice needs
to be changed. For altitudes between 2,000 and 4,500 feet,
both the orifice and the regulator pressure need to be
changed.
Application Brand Part
Number
For use with G7 series gas furnaces using a
Honeywell Gas Valve Frigidaire 904915
For G7MQ Modulating Furnaces
Application Brand Part
Number
For use with G7MQ series gas furnaces Frigidaire 904950