installation instructionsFor Heavy Duty (FAS Models) andMedian (FAM Models) Air Conditioners
Please read ALL instructions before installing. Two people are
recommended to install this product. If a new electrical outlet
is required, have the outlet installed by aqualified electrician
before installing unit, See#5 in Preliminary Instructions
following.

Prelimi nary instru ctions

Do the following before starting to install unit. See illustrations
below.
Check dimenstions of your unit to determine model type:
Heavy duty (FAS) Median (FAM)
Unit Height: 18,5/8" 17.5/8"
Unit Width: 261/2" 231/2"
Min. Window Opening: 19" 181/2"
Min. Window Width: 31" 26 Vj'
Max. Window Width: 43" 40 V2"
1. Check window opening size- the mounting parts furnished
with this air conditioner are made to install in a wooden
sill double-hung window.The standard parts are for
window dimensions listed above.Open sash to a minimum
of 1g"(483mm). (FIG. 1)
2. Check condition of window- all wood parts of window
must be in good shape and able to firmly hold the needed
screws.if not, make repairs before installing unit.

FIG. 1

_1SASH
19" MIN
1/2" MIN
STORM WINDOW FRAME OR
OTHER OBSTRUCTION
FOAM GASKET
WASHERHEAD
LOCKENG SCREW_._._ X
ASSEMBLY
(LEFT)
SIDE RETAENER J
BRACKET
3. Check your storm windows= if you storm window
frame does not allow the clearance required, correct by
adding a piece of wood as shown in FIG.2, or by removing
storm window while room air conditioner is being installed.
(continued)

FIG. 2

// SASH
f
19"MIN
1112
STORM WINDOW FRAME OR WITH TWO NAILS OR
OTHER OBSTRUCTION SCREWS.

P/N 6612990 1162

1