Frigidaire DH400MY5, LD65ELY5, DH300EY5, LD40EY5, DH400EY5, LD40Y5 Control Parts, Power Cord Assembly

Models: DH400EY5 DH305Y5 DH404EY5 DH400MY5 DH300MY5 LD50ELY5 LD40Y5 DH504ELY5 DH300EY5 LD40EY5 LD65ELY5

1 34
Download 34 pages 12.86 Kb
Page 14
Image 14

3.2 CONTROL PARTS

3.2.1 POWER CORD ASSEMBLY

1.After opening the control box, remove the screw that holds the ground wire. (See Figure 15)

2.Disconnect the remaining leads of the power cord from the PWB(PCB) ASSEMBLY, MAIN, then remove it from the control box.

3.2.2 SENSOR ASSEMBLY

1.Disconnect the sensor assembly from the

PWB(PCB) ASSEMBLY, MAIN.

2.Remove the screw which fastens the humidity sensor. (See Figure 16)

3.Remove the thermistor from the holder. (See Figure 16)

4.Disconnect the switch wires from the micro switch assembly. (See Figure 16)

3.2.3 PWB(PCB) ASSEMBLY, MAIN

1.Disconnect all leads of the motor and the compressor from PWB(PCB) ASSEMBLY, MAIN.

2.Remove the screw which fastens the PWB(PCB) ASSEMBLY, MAIN and pull it out after unhooking from 2 rectangular holes of the control box (lower). (See Figure 17)

3.2.4 CAPACITOR

1.Remove the screw that fastens the capacitor. (See Figure 17)

2.Disconnect all leads from the capacitor and then remove it from control box.

3.2.5 MICRO SWITCH ASSEMBLY

1.Turn the nut counterclockwise and pull out the micro switch from the drain pan. (See Figure 18)

—14—

Figure 15

Figure 16

Figure 17

Figure 18

Page 14
Image 14