.Lift the range hood up under cabinet and determine final location by centering beneath cabinet. Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood (See slot dimensions on page 6). Set range hood aside on a covered surface.

AA

A. Keyhole slot

.Use ¹⁄8” (3 mm) drill bit and drill 4 pilot holes as shown. NOTE: Make the drill holes on the thin area of the slot.

A. Drill pilot hole

A

4.Install the 4 - .45 cm x 1.3 cm mounting screws in pilot holes. Leave about ¼” (6.4 mm) space between screw heads and cabinet to slide range hood into place.

¹⁄4”

(6.4 mm)

For roof installations, remove the top rectangular or round vent knockout depending on which vent system you desire to install. For wall installations, remove the rear rectangular vent knockout.

C

A

A. Top rectangular knockout

B

B. Rear rectangular knockout

 

C. Top round knockout

 

INSTALLING THE HOOD

Vent Connector Installation

Install 7” (17.8 cm) round vent mounting plate or 3¼” x 10” (8.3 x 25.4 cm) vent connector, depending on your vent system installation. Attach to range hood using the indicated screws provided in hardware kit.

 

Install the 7” (17.8 cm)

A

round vent mounting plate

B

A. .29 x .65 cm screws

 

B. 7” (17.8 cm) round vent

 

mounting plate.

C

C. Round vent knockout

 

D. Rectangular vent knockout

 

D

 

B

A

Install the 3¼” x 10” (8.3 x

25.4 cm) rectangular vent

 

transition

 

A. 3¼” x 10” (8.3 x 25.4 cm)

 

rectangular vent transition

 

B. .35 x .65 cm screws

 

C. Rectangular vent knockouts

C

A

B

NOTE

The 7” (17.8 cm) round vent mounting plate or the 3¼” x 10” (8.3 x 25.4 cm) rectangular vent connector can be installed up to 1” (2.5 cm) on either side of the hood center to accommodate off center ductwork.

If a vent damper is installed with a wall cap with damper, check that they do not interfere with each other. Remove the vent connector damper flap if they interfere.

Power Supply Cable Installation

1.For direct wire installations, run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances. There must be enough wiring from the fused disconnect (or circuit breaker) box to make the connection in the hood electrical terminal box.

11

Page 11
Image 11
Frigidaire LI30MB manual Installing the Hood, Vent Connector Installation, Power Supply Cable Installation