Frigidaire PLHV36W6KC Appliance Installation, Do not use duct smaller than the transition

Models: PLHV36W6KC

1 24
Download 24 pages 27.59 Kb
Page 6
Image 6
Appliance Installation:

Installation

1"

Starting

Collar

Figure 4

Appliance Installation:

11.Install transition on top of hood if removed for shipping. Figure 4.

12.Hang hood on 2 mounting hooks through the rectangular cutouts on back of hood. Figure 5

13.Level the appliance, using a carpenters level across bottom of hood with leveling screws in mounting hooks or rectangular cutouts.

14.Secure hood with 2 screws on top and 2 screws on bottom. See Figure 5.

15.Connect ducting (Figure 4).

Note: for blower serviceability, leave a gap of 1" minimum between top of transition and sheet metal duct and cover gap with a starting collar wrapped around duct and transition. Locate collar screws so they fit into corner of duct cover. Secure collar to transition and duct with three sheet metal screws each. Seal with duct tape.

Do not use duct smaller than the transition.

13

Figure 5

6

Page 6
Image 6
Frigidaire PLHV36W6KC important safety instructions Appliance Installation, Do not use duct smaller than the transition