INSTALLATION INSTRUCTIONS

8 VENTILATION SYSTEM

(PREPARING OVEN FOR INSTALLATION)

This microwave oven/hood is designed for adaptation to three types of hood ventilation systems. Select the type required for your installation.

RECIRCULATING non-vented, ductless.

Follow installation procedure (A). Recirculating requires the use of the Charcoal Filter, which has already been installed in the oven.

HORIZONTAL EXHAUST — outside ventilation.

Follow installation procedure (B).

VERTICAL EXHAUST — outside ventilation.

Follow installation procedure (C).

(A)RECIRCULATING: NON-VENTED, DUCTLESS OPERATION

1.The unit is shipped assembled for recirculating.

2.The Exhaust Damper Assembly is not required for recirculating exhaust.

3.Charcoal Filter, included with the unit, is required for recirculating exhaust. Attach the Charcoal Filter to the upper side of the oven by sliding into the tabs. See Figure 6. The Charcoal Filter should be replaced every 6 to 12 months, depending on use.

Tabs

(B)HORIZONTAL EXHAUST: OUTSIDE VENTILATION

1.Remove and save 2 screws from back edge and 1 screw from the top center of Fan Cover Bracket. Remove Fan Cover Bracket by sliding it in the opposite direction of the arrow on the Fan Cover Bracket, as shown in Figure 7.

2.Withdraw Hood Fan Unit carefully and slip wires out of Wire Box. See Figure 8.

CAUTION: Do not pull or stretch hood fan wiring.

3.Rotate the Hood Fan Unit and turn end-over-end so that the fan blade openings are facing the back of the oven. Replace Hood Fan Unit into the oven. Be careful not to pinch the lead wire between the inner bracket and the Hood Fan Unit. See Figure 9.

4.Put the lead wire into Wire Box. See Figure 10.

5.Replace the Fan Cover Bracket by sliding it into the slits in the same direction as the arrow on the Fan Cover Bracket. Make sure the fan blades are visible through the rear openings in the oven before proceeding. Attach Fan Cover Bracket to unit with 3 screws, which were removed in Step 1 above. See Figure 11. The Hood Fan Unit is now rotated for horizontal exhaust operation.

6.Attach the Exhaust Damper Assembly to the back of the unit. See Figure 10. Use two Tapping Screws 4 x 8 from the INSTALLATION HARDWARE and tighten into place.

Tabs

Figure 8

Figure 6

Fan Cover Bracket

Back of

Oven

Figure 7

Figure 9

E4

Page 4
Image 4
Frigidaire TINSEB151WRRZ, 316137234 installation instructions Ventilation System, Bhorizontal Exhaust Outside Ventilation