SUPER RUNNER SERIES GAS FRYERS
CHAPTER 1: INSTALLATION INSTRUCTIONS
1-3
AUSTRALIAN REQUIREMENTS:
To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory
regulations.
CE UNITS ONLY:
Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity/Color, Burner Markings
and Pilot Markings are listed in the table below:
MANIFOLD GAS PRESSURE
MODEL*
NOMINAL
HEAT INPUT-
Qn
(kW)
GAS TYPE ORIFICE
SIZE (MM) MBAR INCH W.C.
ORIFICE
QTY/ COLOR BURNER
MARKING PILOT
MARKING
SR62 GM 37.5 G20
G25
G31
2.40
2.40
1.51
12,0
17,5
22,0
4,8
7,0
8,8
5/BLUE
5/BLUE
5/RED
Blue
Blue
Red
26N
26N
16LP
SR52 GM 30 G20
G25
G31
2.40
2.40
1.51
12,0
17,5
22,0
4,8
7,0
8,8
4/BLUE
4/BLUE
4/RED
Blue
Blue
Red
26N
26N
16LP
SR42 GM 26 G20
G25
G31
2.40
2.40
1.51
12,0
17,5
22,0
4,8
7,0
8,8
3/BLUE
3/BLUE
3/RED
Blue
Blue
Red
26N
26N
16LP
*SR prefix- Super Runner Series
*GM suffix- gas millivolt system with no electrical supply connections required
NON-CE UNITS ONLY:
Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity, and Pilot Markings are
listed in the table below:
MODEL*
NOMINAL
HEAT INPUT-
Qn
(BTU)
GAS TYPE ORIFICE
SIZE (MM)
MANIFOLD GAS
PRESSURE
(INCH W.C.)
ORIFICE
QUANTITY PILOT
MARKING
SR62 GM 150 NAT
LP 2.53(#39)
1.51(#53) 4
11 5
5 26N
16LP
SR52 GM 120 NAT
LP 2.53(#39)
1.51(#53) 4
11 4
4 26N
16LP
SR42 GM 105 NAT
LP 2.80(#35)
1.70(#51) 4
11 3
3 26N
16LP
*SR prefix- Super Runner Series
*GM suffix- gas millivolt system with no electrical supply connections required
NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is
operating.
1.4 Connection to the Gas Supply Line
NOTE: The gas supply (service) line must be the same size or greater
than the fryer inlet line. This appliance is equipped with a ½-inch (15-
mm) inlet. The gas supply line must be sized to accommodate all gas-
fired equipment connected to the line. Consult the local gas company
or supplier, or your local contractor for minimum supply line
requirements.
NOTE: If quick-disconnect supply lines or flex lines are used,
increase supply line size to ¾-inch (22-mm) or larger.
Regulator
Propane Applications;
Proper Regulator Must Be Installed