Fujitsu AOU9RL2 specifications Error Detection

Models: AOU9RL2

1 22
Download 22 pages 63.92 Kb
Page 11
Image 11
ERROR DETECTION

ERROR DETECTION

TROUBLESHOOTING

OPERATION lamp (green)

 

 

 

 

 

 

TIMER lamp

 

 

 

 

with the indoor unit display

(orange)

 

Error ECONOMY lamp (green)

 

Error

 

OPERATION

TIMER

ECONOMY

 

 

 

 

 

 

 

Serial communication error

 

1 flash

1 flash

 

 

 

 

 

 

 

 

Indoor unit PCB model information error

 

3

2

 

 

 

 

 

 

 

 

Manual auto switch error

 

3

5

 

 

 

 

 

 

 

 

Room temp. sensor error

 

4

1

 

 

 

 

 

 

 

 

Indoor unit Heat Ex. Middle temp.sensor error

 

4

2

 

 

 

 

 

 

 

 

Indoor unit fan motor error

 

5

1

 

 

 

 

 

 

 

 

Indoor unit error

 

5

15

 

 

 

 

 

 

 

 

Outdoor unit main PCB model

 

6

2

 

 

information error or communication error

 

 

 

 

 

 

 

 

Inverter error

 

6

3

 

 

 

 

 

 

 

 

Active filter error, PFC circuit error

 

6

4

Rapid flash

 

 

 

 

 

(0.1s on

 

Trip terminal L error

 

6

5

 

 

/ 0.1s off)

 

 

 

 

 

 

Display PCB microcomputers communication error

 

6

10

 

 

 

 

 

 

 

 

 

 

Discharge temp. sensor error

 

7

1

 

 

 

 

 

 

 

 

Outdoor unit Heat Ex. liquid temp. sensor error

 

7

3

 

 

 

 

 

 

 

 

Outdoor temp. sensor error

 

7

4

 

 

 

 

 

 

 

 

Current sensor error

 

8

4

 

 

 

 

 

 

 

 

Trip detection

 

9

4

 

 

 

 

 

 

 

 

Compressor rotor position detection error

 

9

5

 

 

 

 

 

 

 

 

Outdoor unit fan motor error

 

9

7

 

 

 

 

 

 

 

 

4-way valve error

 

9

9

 

 

 

 

 

 

 

 

Discharge temp. error

 

10

1

 

 

 

 

 

 

 

 

 

 

(0.5s on / 0.5s off)

 

2012.11.07

10

 

 

Page 11
Image 11