SWING OPERATION

Begin air conditioner operation before performing this procedure.

To select SWING Operation

Press the SWING button (Fig. 6 T).

The SWING Display (Fig. 7 c) will light.

In this mode, the Air Flow Direction Louvers will swing automatically to direct the air flow both up and down.

To stop SWING Operation

Press the SWING button (Fig. 6 T) once again.

The SWING Display (Fig. 7 c) will go out.

Airflow direction will return to the setting before swing was begun.

About Swing Operation

During cooling/Dry mode :

Swings between 1 and 3.

During heating mode

:

Swings between 3 and 7.

The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

COIL DRY OPERATION

The Indoor unit can be dried by pressing the COIL DRY button on the Remote Control Unit so as to avoid going moldy and restrain the breed of bacterium.

The COIL DRY Operation will operate for 20 minutes after pressing the COIL DRY button and it will stop automatically.

To select COIL DRY Operation

Press the COIL DRY button (Fig. 6 M) during operation or when it stops.

The COIL DRY Display (Fig. 7 a) and COIL DRY Indicator Lamp (orange) (Fig. 3 8) will light. Then it will disappear after 20 minutes.

To cancel COIL DRY Operation

Press the START/STOP button (Fig. 6 R) during COIL DRY

Operation.

The COIL DRY Display (Fig. 7 a) and COIL DRY Indicator Lamp (orange) (Fig. 3 8) will go out . Then the operation stops.

About COIL DRY Operation

Press the COIL DRY button again during COIL DRY Operation, COIL DRY Opera- tion can be reset.

The COIL DRY Operation cannot get rid of the existed mould or bacterium, and it has no sterilization effect either.

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable.

How To Use the Main Unit Controls

Press the MANUAL AUTO button (Fig. 2 2) on the main unit control panel.

To stop operation, press the MANUAL AUTO button (Fig. 2 2) once again. (Controls are located inside the Open Panel)

When the air conditioner is operated with the controls on the Main Unit, it will operate under the same mode as the AUTO mode selected on the Re- mote Control Unit (see page 6).

The fan speed selected will be “AUTO” and the thermostat setting will be standard.(76°F)

En-10