Installation Specifications

The following table summarizes the installation specifications of this scanner.
Note) Dimensions
Item Specifications
Dimensions
(Note) Width Depth Height
Minimum 284 mm
11.18 in. 146 mm
5.75 in. 150 mm
5.91 in.
Maximum 284 mm
11.18 in. 480 mm
18.90 in. 302 mm
11.89 in.
Weight 2.7 kg (approxiamtely 5.95 lb)
Input power
supply Voltage 100 - 240 V
Number of
phases Single-phase
Frequency 50/60 Hz
Power con-
sumption During
operation 27 W or less
During standby 8 W or less
Temperature/
Humidity
Allowable
Ranges
Scanner state During operation During standby During storage/
transportation
Temperature 5 to 35 (°C)
41 to 95 (°F) -20 to 60(°C)
-4 to140 (°F) -20 to 60(°C)
-4 to 140 (°F)