Compact Duct 9, 12, 18 and 24,000 BTUs
ARU9RLF, ARU12RLF, ARU18RLF, ARU24RLF
ARU9, 12RLF ARU18RLF ARU24RLF
| ARU9RLF | ARU12RLF ARU18RLF ARU24RLF | ||
| Heat Pump | Heat Pump | Heat Pump | Heat Pump |
Nominal Cooling BTU/h |
|
|
|
|
9,000 | 12,000 | 18,000 | 24,000 | |
Nominal Heating BTU/h | 10,200 | 13,500 | 20,000 | 27,000 |
Voltage/Frequency/Phase | ||||
Recommended Static Pressure In. W. C. | 0 ~ 0.36 | 0 ~ 0.36 | 0 ~ 0.36 | 0 ~ 0.20 |
Air Circ. C.F.M. (m3/h) Clg/Htg: Hi | 353 (600) | 383 (650) | 554 (940) | 783 (1,330) |
Medium | 324 (550) | 353 (600) | 518 (880) | 730 (1,240) |
Low | 294 (500) | 324 (550) | 483 (820) | 648 (1,100) |
Quiet | 265 (450) | 283 (480) | 442 (750) | 607 (1,030) |
Noise Level dB(A) (Clg/Htg): Hi | 28/28 | 29/29 | 32/33 | 33/35 |
Medium | 27/26 | 28/28 | 31/32 | 32/34 |
Low | 26/25 | 27/27 | 30/31 | 30/32 |
Quiet | 25/24 | 26/24 | 29/29 | 29/29 |
Running Current Rated (A): Cooling | 0.30 | 0.35 | 0.44 | 0.66 |
Heating | 0.30 | 0.35 | 0.44 | 0.66 |
Power Use Rated (W): Cooling | 49 | 58 | 73 | 111 |
Heating | 49 | 58 | 73 | 111 |
Fan Speeds Stage | 4 + Auto | 4 + Auto | 4 + Auto | 4 + Auto |
Air Filter | Washable | Washable | Washable | Washable |
Connection Method | Flare | Flare | Flare | Flare |
Conn. Pipe Diameter Inch | suc 3/8 dis 1/4 | suc 3/8 dis 1/4 | suc 1/2 dis 1/4 | suc 5/8 dis 1/4 |
Net Weight lbs. (kg) | 41 (19) | 41 (19) | 50 (23) | 59 (27) |
Dimensions: Height Inch (mm) | ||||
Width Inch (mm) | ||||
Depth Inch (mm) | ||||
Supply Duct Flange | ||||
Dimensions: Height Inch (mm) | ||||
Width Inch (mm) | ||||
Depth Inch (mm) | 3/4 (19) | 3/4 (19) | 3/4 (19) | 3/4 (19) |
Return Duct Flange | ||||
Dimensions: Height Inch (mm) | ||||
Width Inch (mm) | ||||
Depth Inch (mm) | 3/4 (19) (Flat) | 3/4 (19) (Flat) | 3/4 (19) (Flat) | 3/4 (19) (Flat) |
Refrigerant | R410A | R410A | R410A | R410A |
|
|
|
|
|
Compact Duct
Adaptable when ceiling cavity is small and there is no slope for drain.
Traditional
Drain
13”Pump
Compact Duct
9.4”Return Air-intake Choices
Bottom
Back
Standard Features
•Dry Mode
•Weekly Timer
•Sleep Timer*
•
•Minimum Heat Mode*
•Auto Mode
•Quiet Mode
•Auto Restart/Reset
•Auto Changeover
•Condensate Pump
•Fresh Air Intake
*Available only with optional wireless remote control.
Field Supplied Filters Used With Compact Duct Units |
| ||
Compact Duct Units require field supplied filters. They can be installed | CFM | ||
at the unit or for more convenient servicing, in filter grilles. The chart |
| ||
| Typical Filter Size | ||
to the right provides guidelines for determining filter sizes. |
| ||
| Velocity, FPM | ||
|
| Unit External SP, in. W.C. | |
Filters are sized to keep velocities and |
|
| SP Loss, in. W.C. |
static pressure loss low. This will insure |
|
| |
| Available Static Pressure | ||
sufficient static pressure is available for |
| ||
|
| SP Loss, in. W.C. | |
ductwork, fittings and supply and return |
|
| |
| Available Static Pressure | ||
grilles. lternative filter sizes with |
| ||
|
|
| |
equivalent face areas can be used. |
|
| SP Loss, in. W.C. |
After deducting filter loss, available | A fiberglass filter is shown in | Available Static Pressure | |
static pressure values are shown. | blue to the left. A MERV pleated |
|
|
| filter is shown in white. |
|
|
ARU | ARU | ARU | ARU |
9RLF | 12RLF | 18RLF | 24RLF |
353 | 353 | 547 | 806 |
12 x 20 | 12 x 20 | 14 x 25 | 18 x 30 |
212 | 212 | 225 | 215 |
0.36 | 0.36 | 0.36 | 0.20 |
| 1" Fiberglass Filter |
| |
0.04 | 0.04 | 0.04 | 0.04 |
0.32 | 0.32 | 0.32 | 0.16 |
1" MERV 8 Pleated Filter | |||
0.12 | 0.12 | 0.14 | 0.13 |
0.24 | 0.24 | 0.22 | 0.07 |
2" MERV 8 Pleated Filter | |||
0.07 | 0.07 | 0.08 | 0.07 |
0.29 | 0.29 | 0.28 | 0.13 |