2

Note – AC power supply model and DC power supply model are available for the M3000 server. The

chapters of each document are written based on AC power supply model. If there is any specific

information on DC power supply model, it is indicated in the appendix “DC Power Supply Model“ of

each document. Be sure to see the appendix when you use DC power supply model.

Installation Steps for SPARC Enterprise M3000 Server
For quick installation and configuration, follow these steps. For more detailed information, see the SPARC
Enterprise M3000 Server Installation Guide.
1. Verify power, air conditioning, and floor area requirements.
Prepare adequate power equipment according to the type of power supply to your server model. For
details, see the SPARC Enterprise M3000 Server Site Planning Guide.
2. Prepare items required for installing the server.
3. Check the delivered items against the “LIST OF ATTACHMENT” that came with the server.
4. Set up the equipment rack and mount the M3000 server.
See the SPARC Enterprise Equipment Rack Mounting Guide.
Caution – Make sure that the power source circuit breaker is in the OFF position before connecting
the power cords.
5. Connect the power cords to the power supply units on the rear panel of the server.
Make sure that each power cord is connected to the server and secured with a cord clamp.
6. Connect the power cords to the power supply system.
The requirements for connecting power cords vary depending on the type of power supply to your server
model. For details, see the SPARC Enterprise M3000 Server Installation Guide.
AC power supply model
The AC power supply model of the M3000 server is shipped with two grounding-type (three-wire)
power cords. Always connect the power cords into grounded power outlets.
DC power supply model
The DC power supply model of the M3000 server is shipped with two DC power cords. Since these DC
power cords have a connector only for the server end, a terminal matching the DC power supply
equipment will need to be attached to the DC power supply end of the cord. Moreover, the power
supply equipment must be correctly grounded.
Administration • SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Product Notes
• SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Administration Guide
• SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide
• SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers XSCF Reference Manual
Repair and
Troubleshooting
• SPARC Enterprise M3000 Server Service Manual
• SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers Administration Guide
Globalization For SPARC Enterprise M3000 server, the documents of localized versions will be offered on the
website:
http://www.fujitsu.com/sparcenterprise/manual/