cfgdevice(8)

The current status of the drive that is displayed with this command includes the following types of status information:

port_no

Port number of the port where the IOUA is installed and that

 

can be connected to a DVD/TAPE drive. It is displayed in the

 

"IOU number-PCI slot number" format.

IOU/SAS-statusConnection status between IOUA and built-in switching unit. It is changed by specifying "attach" or "detach."

enable/disable: Setting status of the cfgdeive(8) command

enable: Connected with "-c attach."

disable: Not connected.

up/down: Logical connection between IOUA and built-in switching unit.

up: Connected.

down: Not connected.

SAS-statusConnection status between I/O unit and the system.

enable/disable: Connection setting between I/O unit and the system. When starting a domain with no I/O unit, the "disable" may be displayed.

enable: Yes

disable: No

up/down: Logical connection between I/O unit and the system.

up: Connected.

down: Not connected.

The cfgdevice(8) command is valid only for high-end server.

Privileges You must have one of the following privileges to run this command:

For connection and disconnection: platadm, fieldeng

For displaying the status: platadm, fieldeng

Refer to setprivileges(8) for more information.

22

XSCF Reference Manual • Last Revised January 2007