clockboard(8)

NAME clockboard - Set or display the clock control unit used at system startup

SYNOPSIS clockboard -cdisplay

clockboard -cset -sCLKU_B-number clockboard -h

DESCRIPTION The clockboard(8) command specifies the clock control unit used when the system power is turned on, or it displays the clock control unit that is currently used and the clock control unit used at the next system startup.

The number 0 or 1 is used to specify or display a clock control unit. When the clockboard(8) command is executed with no options, the clock control unit that is currently used and the one used at the next system startup are displayed.

The clockboard(8) command is valid only for duplicated configuration of the clock control unit.

Privileges You must have fieldeng privilege to run this command.

Refer to setprivileges(8) for more information.

OPTIONS The following options are supported:

-h

Displays usage statement. When used with other options or

 

operands, an error occurs.

-sCLKU_B-numberSpecifies the clock control unit to be used the next time the system power is turned on. Either 0 or 1 can be specified for CLKU_B-number.

EXAMPLES

EXAMPLE 1 Displays the clock control unit that is currently used and the one used at the

 

next system startup.

 

XSCF> clockboard

 

 

current CLKU_B number

:0

 

next CLKU_B number

:1

EXAMPLE 2 Specifies the clock control unit used at the next system startup.

XSCF> clockboard -s 1

EXIT STATUS The following exit values are returned:

0

Successful completion.

>0

An error occurred.

System Administration

27