fmstat(8)

XSCF> fmstat

module

ev_recv ev_acpt wait

svc_t

%w

%b

open solve memsz

 

bufsz

 

 

 

 

 

 

 

 

 

 

 

case-close

 

0

0

0.0

0.0

0

0

0

0

0

0

fmd-self-diagnosis

1

1

0.0

0.2

0

0

1

0

27b

0

sysevent-transport

0

0

0.0

573.2

0

0

0

0

0

0

syslog-msgs

 

0

0

0.0

0.0

0

0

0

0

97b

0

EXAMPLE 2 Displaying FM Statistics for fmd Self-Diagnosis Module

XSCF> fmstat -z -m fmd-self-diagnosis

NAME VALUE

DESCRIPTION

module 1

error events received from fmd modules

EXIT STATUS The following exit values are returned:

0

Successful completion.

>0

An error occurred.

SEE ALSO fmadm(8), fmdump(8)

64