ioxadm(8)

NAME ioxadm - manage External I/O Expansion Units

SYNOPSIS ioxadm [-f] [-p] [-v] [-M] env [-e] [-l] [-t] [ target [ sensors]]

ioxadm [-f] [-p] [-v] [-M] list [ target]

ioxadm [-f] [-p] [-v] [-M] locator [onoff] [ target]

ioxadm [-f] [-p] [-v] [-M] poweroff target

ioxadm [-f] [-p] [-v] [-M] poweron target

ioxadm [-f] [-p] [-v] [-M] reset target

ioxadm [-f] [-p] [-v] [-M] setled [ onoffslowfast] target led_type

ioxadm -h

DESCRIPTION ioxadm(8) manages External I/O Expansion Units and link cards attached to the system.

For this utility, an operand with parameters and a target device must both be specified. The target device can be a downlink card mounted in a built-in PCI slot in the host system; an External I/O Expansion Unit; or a field replaceable unit (FRU) in an External I/O Expansion Unit. The downlink card is identified by a string which identifies the host path to the card. An uplink card is a FRU in the I/O boat.

Privileges You must have one of the following privileges to run these commands:

Required Privileges

Commands

 

 

platop

env, list

 

 

platadm

locator, poweroff, poweron

 

 

fieldeng

reset, setled

 

 

Refer to setprivileges(8) for more information.

OPTIONS The following options are supported.

-f

Forces command execution by ignoring warnings.

-h

Displays usage statement.

 

When used with other options or operands, an error occurs.

System Administration