Fujitsu MHV2080AH, MHV2100AH 3 System level and field troubleshooting, Maintenance and Diagnosis

Models: MHV2040AH MHV2080AH MHV2060AH MHV2100AH

1 40
Download 40 pages 3.03 Kb
Page 26
Image 26
Table 1.3 System level and field troubleshooting

Maintenance and Diagnosis

 

Table 1.3 System level and field troubleshooting

 

 

Check to be made

Recommended work

 

 

DC power voltage

Confirm that the DC power voltage is within ±5% of the standard value.

level

When measured at pins 41, 42 and 43 of the power supply connector, the

 

+5 VDC must be 4.75 to 5.25 VDC.

 

 

DC power ripple

Check that the maximum ripple at +5 VDC power is less than 100 mV

noise

peak to peak and 200 mV peak to peak respectively.

 

 

Power-interface

Confirm that the AT interface cable is properly connected at the disk

cable connection

drive, power supply section, and control unit.

 

 

Switch setting

Confirm that the switch on the interface connector at the disk drive

 

control PCA is set for normal operation with the host computer. Refer to

 

Section 3.4 of the MHV2100AH, MHV2080AH, MHV2060AH,

 

MHV2040AH Disk Drives Product Manual for switch setting.

 

 

System cable

Confirm that all cable connections throughout the system correctly

 

connected.

 

 

System diagnostic

To further isolate the failure, if it can be done, execute the system level

test

diagnostic routine described in the host computer manual.

 

 

Intermittent or

Check the AC voltage level at the power supply section and recheck the

indefinite error

DC voltage level at the disk drive power supply connector.

 

If the AC voltage level is abnormal, or if there is a lot of electrical noise,

 

notify the user.

 

If the DC voltage level is unstable, replace the power supply section.

 

If possible, replace the disk drive. If the fault remains, the disk drive is

 

not the case. For suggestions to isolate the failure further, refer to the

 

hardware and software manuals provided with the system.

 

 

1-12

C141-F071

Page 26
Image 26
Fujitsu 3 System level and field troubleshooting, 4 of the MHV2100AH, MHV2080AH, MHV2060AH, Maintenance and Diagnosis