DESCRIPTION OF INPUT TERMINALS

DVI-D terminal (RGB1 INPUT/DVI-D)

Pin No.

 

Signal

Pin No.

 

Signal

Pin No.

Signal

for the W/U/A models

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

T.M.D.S. Data2–

9

 

T.M.D.S. Data1–

17

T.M.D.S. Data0–

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

T.M.D.S. Data2+

10

 

T.M.D.S. Data1+

18

T.M.D.S. Data0+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

T.M.D.S. Data2

11

 

T.M.D.S. Data1

19

T.M.D.S. Data0

 

 

 

 

 

 

Shield

 

 

Shield

 

 

 

Shield

 

 

 

 

 

4

12

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

13

 

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

DDC Clock

14

 

+5V Power

22

T.M.D.S. Clock Shield

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

DDC Data

15

 

Ground (for +5V)

23

T.M.D.S. Clock+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

16

 

Hot Ploug Detect

24

T.M.D.S. Clock–

mD-sub input terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin No.

Input signal

Pin No.

 

Input signal

 

(RGB2 INPUT/mD-sub) for the W/U/A models

 

 

(RGB1 INPUT/mD-sub) for the R model

1

 

Red

 

9

 

 

 

 

 

 

 

 

 

 

2

 

Green

 

10

 

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

Blue

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

Ground

 

13

 

 

Horizontal synchronization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

Ground

 

14

 

 

Vertical synchronization

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

Ground

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

Ground

 

Frame

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232C terminal (RS-232C)

Pin No.

Signal

 

 

1

DCD (Data Carrier Detect)

 

2

RD (Received Data)

 

3

TD (Transmit Data)

 

4

DTR (Data Terminal ready)

 

5

GND (Ground)

 

6

DSR (Data Set Ready)

 

7

RTS (Request To send)

 

8

CTS (Clear To Send)

 

9

RI (Ring Indication)

Póññêèé Português Italiano Français Español Deutsch English

÷–Œƒ

日 本 語

Downloaded From TV-Manual.com Manuals

E-7

Page 7
Image 7
Fujitsu P42VHA40U, P42HHA40A, P42HHA40W, P42HHA40U Description of Input Terminals, Pin No Signal, Pin No Input signal

P55XHA40U, P50XHA40U, P63XHA40A, P55XHA40W, P42HHA40U specifications

Fujitsu has a reputation for delivering cutting-edge HVAC solutions, and their latest models, the P63XHA40W, P63XHA40U, P50XHA40W, P42VHA40U, and P42HHA40W, continue this tradition with advanced features and technologies that prioritize comfort, efficiency, and sustainability.

The P63XHA40W and P63XHA40U are standout units designed for larger spaces, boasting impressive cooling and heating capacities that ensure optimal climate control in even the most demanding environments. Equipped with inverter technology, these models offer variable-speed operation, which adjusts the compressor speed according to the desired temperature, resulting in significant energy savings while maintaining a stable indoor climate.

Similarly, the P50XHA40W offers robust performance tailored for mid-sized applications. With a focus on energy efficiency, this model incorporates an advanced heat exchanger design, which enhances thermal conductivity and overall performance. The unit also features a user-friendly control interface, enabling homeowners and businesses to easily adjust settings for maximum comfort.

For smaller environments, the P42VHA40U and P42HHA40W provide efficient heating and cooling solutions that do not compromise on performance. Both models are equipped with features like air purification systems that enhance indoor air quality by removing dust and allergens. Additionally, efficient filtration systems ensure that the air circulated is not only comfortable but also healthier for occupants.

All five models leverage Fujitsu's environmental commitment by minimizing refrigerant use and adopting low-GWP refrigerants. This approach helps reduce the overall carbon footprint, aligning with global efforts to combat climate change. Furthermore, the units are designed with whisper-quiet operation in mind, so users can enjoy a peaceful environment without the disruptive sounds often associated with traditional HVAC systems.

Installation flexibility is another key characteristic of these Fujitsu models. They can be easily integrated into various settings, from residential homes to commercial buildings, allowing for a seamless fit in any architecture. Durability and reliability are also hallmarks of these units, as they are built to withstand diverse operating conditions while delivering consistent performance over their lifespan.

In summary, the Fujitsu P63XHA40W, P63XHA40U, P50XHA40W, P42VHA40U, and P42HHA40W are exemplary HVAC solutions that combine cutting-edge technology with energy efficiency. With features designed to enhance comfort and sustainability, they represent Fujitsu's ongoing commitment to innovation in climate control.